Journal of chromatography. A

Evaluating the applicability of electrical asymmetrical flow field-flow fractionation for electrophoretic mobility and zeta potential measurements of viral bionanoparticles.

Katri Eskelin, Minna M Poranen

Department of Molecular and Integrative Biosciences, Faculty of Biological and Environmental Sciences, University of Helsinki, Viikinkaari 9B, Helsinki, FI-00014, Finland. Electronic address: katri.eskelin@helsinki.fi. · Department of Molecular and Integrative Biosciences, Faculty of Biological and Environmental Sciences, University of Helsinki, Viikinkaari 9B, Helsinki, FI-00014, Finland.

Key points

From the paper's conclusion
  • We examined the electrophoretic mobility and ζ-potential of virus particles using electrical asymmetric flow field-flow fractionation (EAF4).

Abstract

Viruses and virus-like particles are widely used in biotechnology and biomedicine and their behaviour in these contexts is strongly influenced by their electrokinetic surface properties, particularly charge. We examined the electrophoretic mobility and ζ-potential of virus particles using electrical asymmetric flow field-flow fractionation (EAF4). Enveloped bacteriophage phi6 with two inner protein layers and bacteriophage PRD1 with a proteinaceous capsid and an internal membrane were used as model particles. In EAF4, accurate determination of electrophoretic mobility and ζ-potential depends on reliable retention time measurements obtained at 0 mA and at negative or positive currents. We examined experimental conditions that would enable reproducible retention behaviour. Our results highlight the importance of sufficient buffering capacity in the carrier liquid, while also showing that low total ionic strength increases the magnitude of peak drift. The usable current range was narrow: currents below -10 mA produced unstable detector signals, whereas at +6 mA viruses were inactivated. In optimized conditions, the reproducibility was relatively good and further improved when ζ-potential values were calculated from experiments that used similar current-combination configurations and included more than two applied currents in addition to the 0 mA measurement. Comparison of intact phi6 virions with particles lacking the viral surface protein indicated that the infectious virions carry a less negative surface charge. For PRD1, genome-filled and empty particles exhibited similar electrophoretic mobilities and ζ-potential, but the values were more negative than those of phi6. Finally, we identified factors contributing to measurement variability and provide practical measures to improve reliability while minimizing sample consumption.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers