Polyethylene glycol-modified MIL-88B(Fe) coating for headspace solid-phase microextraction of C6-C10 aldehydes in exhaled breath.
Ke-Rong Wang, Yu-Fei Bai, Xiao-Ye Chang, Yun-Kai Lv, Li-Qing Yu
Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002, China. · Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002, China. Electronic address: yuliqinghbdx@126.com.
Key points
From the paper's conclusion- A polyethylene glycol (PEG)-modified MIL-88B(Fe) composite was synthesized by a one-pot route and evaluated as a coating for headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) for the determination of five C6-C10 aldehydes.
Abstract
A polyethylene glycol (PEG)-modified MIL-88B(Fe) composite was synthesized by a one-pot route and evaluated as a coating for headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) for the determination of five C6-C10 aldehydes. Among the materials prepared at PEG/Fe3+ molar ratios of 0, 5, 10, and 15%, PEG10@MIL-88B(Fe) produced the highest peak areas for all five aldehydes. Characterization by powder X-ray diffraction, Fourier-transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis, X-ray photoelectron spectroscopy, and N2 adsorption-desorption analysis supported PEG modification while retaining the structural characteristics of MIL-88B(Fe). Under the optimized conditions, the developed method provided enrichment factors of 2563-15,562. Calibration curves were linear over 0.1-500 ng mL-1 (R2 = 0.9911-0.9988), with LODs of 0.018-0.030 and LOQs of 0.059-0.099 ng mL-1 of calibration solution (liquid-standard-equivalent). Intra-day, inter-day, fiber-to-fiber, and batch-to-batch RSDs were 3.9-5.9%, 4.2-8.2%, 4.0-9.8%, and 5.3-10.1%, respectively. The method showed limited interference from representative breath volatile organic compounds, with relative responses of 89.30-92.02%, while matrix effects ranged from 94.7% to 104.1%. After 110 extraction/desorption cycles, the coating retained 87.9-93.9% of its initial response. The PEG10@MIL-88B(Fe)-coated SPME fiber was applied to exhaled-breath samples, with spike recoveries of 87.2-105.5%, supporting its applicability to the trace determination of C6-C10 aldehydes in exhaled breath.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Solvent-coordination-triggered framework breathing enables rapid polychlorinated biphenyls elution from magnetic Fe3O4/MIL-88B(Fe) composites.RSC advances · 2026
- MIL-68(Al)-Embedded Polymer Monolith in Pipette Tips for Simultaneous Extraction of the Early- and Late-Stage Aflatoxin B1 Precursors Averantin and Sterigmatocystin from Rice.Molecules (Basel, Switzerland) · 2026
- A 3D Multiarm PEG/Aptamer-Engineered Interface with Superior Antifouling and Selectivity for Trace Aflatoxin Profiling.Analytical chemistry · 2026
- A stir-bar adsorbent of polydopamine-coated melamine sponge incorporating MIL-125 for the extraction of estrogens in milk.Journal of chromatography. A · 2026
- Epoxy–Acrylate Functionalized Cellulose Aerogels: Physisorption‐Driven Surface Engineering for Enhanced Dye Adsorption in Water Treatment ApplicationsWater Environment Research · 2026
- Ultrasensitive Breath Analysis of Lung Cancer Biomarkers Using a Carboxyl-Functionalized Hyper-cross-linked Polymer-Based SPME Coupled with GC─MS.Analytical chemistry · 2026