Journal of chromatography. A

Analysis of mineral oil hydrocarbons in dry foods by silver ion planar solid phase extraction with ultraviolet/fluorescence detection and gas chromatography.

Jonathan Schäfer, Lennart Eichele, Claudia Oellig

Department of Food Chemistry and Analytical Chemistry (170a), Institute of Food Chemistry, University of Hohenheim, Garbenstrasse 28, Stuttgart, 70599, Germany; Institute of Food Chemistry and Food Biotechnology, Justus Liebig University, Heinrich-Buff-Ring 17, Giessen, 35392, Germany. · Department of Food Chemistry and Analytical Chemistry (170a), Institute of Food Chemistry, University of Hohenheim, Garbenstrasse 28, Stuttgart, 70599, Germany.

Key points

From the paper's conclusion
  • Based on a recently developed screening approach for the analysis of mineral oil saturated and mineral oil aromatic hydrocarbons (MOSH and MOAH) in lipid-rich food matrix (vegetable oil) using silver ion planar solid phase extraction with ultraviolet/fluorescence detection (Ag-pSPE-UV/FLD), an approach was developed for dry food samples with low fat content.

Abstract

Based on a recently developed screening approach for the analysis of mineral oil saturated and mineral oil aromatic hydrocarbons (MOSH and MOAH) in lipid-rich food matrix (vegetable oil) using silver ion planar solid phase extraction with ultraviolet/fluorescence detection (Ag-pSPE-UV/FLD), an approach was developed for dry food samples with low fat content. Different fluorescent dyes were investigated for MOSH detection, and berberine was identified as the best humidity-independent option. The performance criteria calculated for the Ag-pSPE-UV/FLD method were a decision limit (LC) of 0.10 mg kg-1, a detection limit (LOD) of 0.20 mg kg-1, and a quantification limit (LOQ) of 0.36 mg kg-1 for MOSH, with recoveries around 91%. For MOAH, the LC was calculated to be 0.03 mg kg-1, the LOD was 0.05 mg kg-1, and the LOQ 0.08 mg kg-1, with recoveries around 96%. As an additional option, the pSPE was hyphenated with gas chromatography-flame ionization detection (GC-FID). For quantification using Ag-pSPE-GC-FID, suitable internal standards were identified with squalane for MOSH and o-terphenyl for MOAH quantification. LOD and LOQ for MOSH were calculated to be 0.13 and 0.42 mg kg-1, respectively and for MOAH, LOD and LOQ were determined to be 0.11 and 0.35 mg kg-1, respectively. Quantification of dry food samples using Ag-pSPE-UV/FLD and Ag-pSPE-GC-FID yielded results similar to those of the routine LC-GC-FID method.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers