Noise‑robust moving window ANOVA algorithm for accurate peak detection and fraction collection in preparative liquid chromatography.
Baolei Wang, Jiangcen Sun, Hao Wang, Zhaosong Ge, Duxin Li
College of Pharmaceutical Science, Soochow University, Suzhou, 215123, PR China; Soochow High-Tech Chromatography Co., Ltd, Suzhou, 215123, PR China. · College of Pharmaceutical Science, Soochow University, Suzhou, 215123, PR China.
Key points
From the paper's conclusion- MW-ANOVA provides a practical, statistically grounded solution for peak detection in preparative and medium-pressure LC, especially for broad, asymmetric, and low-amplitude peaks.
Abstract
Preparative liquid chromatography (prep-LC) is essential for purifying natural products and pharmaceuticals, but accurate real-time peak detection remains challenging under high-noise, high-flow-rate conditions. Conventional threshold- and derivative-based algorithms often fail to detect shallow, slowly rising peaks because signal changes are masked by baseline fluctuations, and smoothing preprocesses can blur genuine peak features. To overcome these limitations, we developed a moving-window analysis of variance (MW-ANOVA) algorithm that performs an F-test on two consecutive subgroups within a sliding window to distinguish systematic chromatographic trends from random noise. The method requires no peak-shape assumptions or prior denoising. We evaluated MW-ANOVA on analytical-scale symmetric standards, on preparative-scale separation of Houttuynia cordata extract, and on medium-pressure liquid chromatography (MPLC) purification of Lonicera japonica. In the preparative separation, MW-ANOVA reliably detected shallow peaks that were missed by the first derivative method, with a minimum detectable slope of approximately 0.07 mV per data point. It guided automated collection of 28 fractions, three of which showed area percentage purities above 93 % at 254 nm. In the MPLC run, bubble peaks and broad elution profiles were present; MW-ANOVA correctly identified the true elution peaks and ignored bubble peaks, whereas the first-derivative method produced 159 mostly false-positive peaks and the fixed-threshold method failed to define correct boundaries. The algorithm was also robust against gradient-induced baseline drift. MW-ANOVA provides a practical, statistically grounded solution for peak detection in preparative and medium-pressure LC, especially for broad, asymmetric, and low-amplitude peaks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- General-Purpose Algorithm for Baseline Correction Based on Inscribed PolynomialsAnalytical Chemistry · 2026
- Aletheia: an open-source pipeline for QC dilution-based feature filtering in untargeted LC-MS metabolomics and lipidomics.Metabolomics : Official journal of the Metabolomic Society · 2026
- Automated Baseline-Correction and Signal-Detection Algorithms with Web-Based Implementation for Thermal Liquid Biopsy Data AnalysisCancers · 2025
- Accuracy of methods for integrating overlapping chromatographic peaks: A systematic evaluation.Journal of chromatography. A · 2026
- An improved peak detection algorithm combining wavelet transform and image segmentation.The Review of scientific instruments · 2026
- Processing of non-targeted LC-HRMS data: Progress and challenges in automated data-driven optimisationsTrAC Trends in Analytical Chemistry · 2026