Chemosphere

Investigating short-term variations of per- and polyfluoroalkyl substances (PFAS) in four Australian wastewater treatment plants.

Mulugeta Legesse Akele, Zahra Sobhani, Madara Weerasooriyagedra, Jaye Marchiandi, Jordan M Partington, Wejdan Alghamdi, Stefano Freguia, Bradley O Clarke

Australian Laboratory for Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria, 3010, Australia; Department of Chemistry, College of Natural and Computational Sciences, University of Gondar, P. O. Box 196, Gondar, Ethiopia. · Australian Laboratory for Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria, 3010, Australia.

Key points

From the paper's conclusion
  • These findings address a globally relevant monitoring challenge by showing that catchment sources and hydraulic scale can outweigh short-term variability.

Abstract

Per- and polyfluoroalkyl substances (PFAS) monitoring at wastewater treatment plants (WWTPs) often relies on isolated samples, obscuring the relative importance of short-term fluctuations and persistent catchment sources. 24-h composite influent and effluent samples were collected over seven consecutive days at four Australian WWTPs during autumn and spring 2023. Median concentrations of the sum of 47 target PFAS (Σ47PFAS) ranged from 11 to 71 ng L-1 at W1-W3, where perfluoroalkyl carboxylic acids (PFCA) predominated, but reached 415-507 ng L-1 at W4. At W4, perfluoroalkane sulfonic acids (PFSA) accounted for 83-85% of Σ47PFAS, dominated by PFHxS and PFOS (73-76%), suggesting a distinct fingerprint potentially linked to groundwater contaminated by electrochemically fluorinated aqueous film-forming foams. Influent-effluent patterns varied among plants and seasons, where Σ47PFAS concentrations in effluent were generally higher, except at W1 in autumn and W4 in spring, and short-chain PFCAs were enriched in effluent. Despite isolated site- and stream-specific differences, daily Σ47PFAS concentrations were broadly stable, while plant-to-plant variation remained noticeable. Estimated annual effluent discharge from individual WWTPs ranged from 0.01 kg year-1 at W3 to 13 kg year-1 at W1. Although W4 had the highest PFAS concentrations, its comparatively low effluent flow limited its total annual discharge to approximately 2 kg year-1. When normalised to the population served, however, W4 had the highest per capita effluent load (137 μg d-1 person-1). Using W3 as a domestic reference (5 μg d-1 person-1) suggests that Australian households contribute approximately 34 kg of PFAS to wastewater each year. These findings address a globally relevant monitoring challenge by showing that catchment sources and hydraulic scale can outweigh short-term variability. Population-normalised domestic baselines offer a transferable framework for detecting non-domestic hotspots, designing representative monitoring and prioritising upstream PFAS controls worldwide.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Investigating short-term variations of per- and polyfluoroalkyl substances (PFAS) in four Australian wastewater treatment plants — Science Skim