EsoEinstein: A Multimodal AI System Integrating EGD and FLIP for Esophageal Motility Assessment.
Evandros Kaklamanos, Kristjana Kristinsdottir, Priyanka Soni, David Melnick, Wenjun Kou, Rajesh N Keswani, Dustin Carlson, Mozziyar Etemadi,
Griffin Esophageal Center, Digestive Health Institute, Northwestern Medicine, Chicago, Illinois. Electronic address: evandros.kaklamanos@nm.org. · Griffin Esophageal Center, Digestive Health Institute, Northwestern Medicine, Chicago, Illinois.
Key points
From the paper's conclusion- Multimodal AI that integrates endoscopic and FLIP data achieves expert-level accuracy and has potential as a less invasive approach for diagnosing achalasia. To realize this potential, future work must validate the system in real-world settings to evaluate its impact on diagnostic timelines and longitudinal patient outcomes.
Abstract
BACKGROUND & AIMS: Achalasia diagnosis relies on integrating endoscopic, functional, and physiologic testing, yet high-resolution manometry (HRM) is invasive, uncomfortable, and resource limited. Artificial intelligence (AI) offers a potential pathway to streamline this workflow. This study aimed to develop and validate AI models for diagnosing achalasia using esophagogastroduodenoscopy (EGD), Functional Lumen Imaging Probe (FLIP) panometry, and their combined multimodal integration, using Chicago Classification v4.0 (CCv4.0) as the reference standard. METHODS: In this retrospective study, 1,802 adult patients who underwent HRM and had available EGD and/or FLIP data at a tertiary center were included. Separate deep learning models were trained for EGD videos, FLIP heatmap images, and a multimodal transformer that integrated both modalities. Primary outcomes were sensitivity, specificity, and AUC for detecting achalasia. RESULTS: The 1,802-patient cohort was partitioned into training (n=1,522), validation (n=212), and test sets (n=68) for model development and evaluation. For the test set, the EGD model achieved sensitivity 0.724, specificity 0.974, and AUC 0.908. FLIP achieved sensitivity 0.862, specificity 0.821, and AUC 0.931. The multimodal model performed the best, with sensitivity 0.931, specificity 0.846, and AUC 0.969. Cochran's Q test found no statistically significant differences across models. CONCLUSION: Multimodal AI that integrates endoscopic and FLIP data achieves expert-level accuracy and has potential as a less invasive approach for diagnosing achalasia. To realize this potential, future work must validate the system in real-world settings to evaluate its impact on diagnostic timelines and longitudinal patient outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence for Diagnosis of Esophageal Manometry: A Narrative Review.Current gastroenterology reports · 2026
- A Clinically Weighted Transformer-Based Deep Learning Model for Automated FLIP Panometry v2.0 Interpretation.Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association · 2026
- The development and validation of artificial intelligence model to assess the degree of mucosal cleanliness of the upper gastrointestinal tract.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2026
- Practical Application of EndoFLIP in the Evaluation of Patients with Dysphagia.Diagnostics (Basel, Switzerland) · 2026
- Clinical Spectrum of Esophageal Motility Disorders in Nonobstructive Dysphagia: A Multicenter, Multiethnic Study.Journal of gastroenterology and hepatology · 2026
- Deep Learning-Assisted Diagnosis of Middle Ear Diseases in Otoendoscopy Across Clinician Experience Levels: Retrospective Reader Study.JMIR medical informatics · 2026