Contemporary clinical trials

BF-PoP: Incorporating backfilling into Posterior Predictive design (PoP) for Phase I clinical trials.

Yuanyuan Han, Xiaochen Zhu, Yiwei Li, Liangang Liu, Daniel Li, Shu-Pang Huang

Bristol Myers Squibb, 3551 Lawrenceville Rd, Lawrence Township, NJ 08648, United States of America. Electronic address: yuanyuan.han@bms.com. · Bristol Myers Squibb, 3551 Lawrenceville Rd, Lawrence Township, NJ 08648, United States of America.

Trial · Phase I

Key points

From the paper's conclusion
  • These results support BF-PoP as an efficient and practically calibratable framework for early-phase oncology dose optimization.

Abstract

Modern early-phase oncology trials face the dual challenge of accurately identifying the maximum tolerated dose (MTD) while generating sufficiently rich data to support recommended phase II dose (RP2D) optimization. To address this, we propose the Posterior Predictive design with backfilling (BF-PoP), which integrates backfilling into the globally optimal decision-making framework of the Posterior Predictive (PoP) design. BF-PoP uses predictive Bayes factors for dose transition and conflict resolution, distinguishes toxicity-based exclusion from backfill eligibility for safe and active lower doses, and provides practical calibration guidance for the parameters C and E. It also enables pre-calibrated decision tables that can meet regulatory safety expectations without ad hoc hard-coding of dose-transition boundaries. Operating characteristics of the design were assessed across 12 dose-toxicity and dose-response scenarios, comparing BOIN, BF-BOIN, PoP, and BF-PoP under inverse-variance-weighted final MTD selection; additional sensitivity analyses evaluated sample-size-weighted isotonic regression, additional target DLT rate, early elimination with near-zero E values, and a range of C values. Simulation results demonstrate that the proposed BF-PoP preserves competitive MTD selection accuracy, increases patient allocation to active sub-MTD doses, and generates dose-optimization data with shorter average trial duration than standard PoP in the evaluated scenarios. These results support BF-PoP as an efficient and practically calibratable framework for early-phase oncology dose optimization.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

BF-PoP: Incorporating backfilling into Posterior Predictive design (PoP) for Phase I clinical trials — Science Skim