Optimising thermal imaging for clinical assessment of burn depth and healing monitoring.
Yuliya Fomenko, Galyna Shustakova, Eduard Gordiyenko, Maksim Liul, Grygorii Oliynyk, Oleksandr Hriazin, Aslan Tsogoev, Oleksii Kravtsov,
B. Verkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of Ukraine, 47 Nauky Ave, Kharkiv, 61103, Ukraine. Electronic address: yufomenko@gmail.com. · B. Verkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of Ukraine, 47 Nauky Ave, Kharkiv, 61103, Ukraine. Electronic address: shustakova@ilt.kharkov.ua.
Key points
From the paper's conclusion- The proposed thermal image processing enabled objective assessment of burn depth and facilitated non-invasive monitoring of wound healing. The developed model showed high prognostic performance and substantial agreement with the final clinical outcomes. Further validation in larger prospective cohorts is needed to support the development of standardised protocols.
Abstract
BACKGROUND: Infrared thermography (IRT) is a promising method for burn depth assessment and monitoring of wound healing. However, its clinical application is limited by the absence of standardised imaging and processing protocols. This study aimed to optimise thermal image analysis for heterogeneous burns and to develop a quantitative model for burn depth assessment and monitoring of wound progression using IRT. METHODS: A prospective longitudinal cohort study was conducted at a burn centre in Kharkiv, Ukraine. Patients were examined using a self-developed infrared camera (array 384 × 288, 0.07 °C sensitivity, 1 mrad spatial resolution). Temperature parameters of burns recorded within three days post-injury were used to develop a prognostic model, with final clinical outcome serving as the reference standard. Prognostic performance was assessed by ROC analysis. Burn healing was monitored by changes in the relative temperature of the wound. RESULTS: Sixty-five adults with 115 burn wounds were enrolled. Of 65 wounds assessed within the first three days, 48% healed within 21 days, while 52% did not heal or underwent skin grafting within 21 days. A relative temperature threshold of ΔTcut-off = -2.4 °C (p < 0.00001) distinguished deep dermal and full-thickness burns (τ ≥ 21 days) from superficial and mixed burns. The prognostic model demonstrated 83.3% sensitivity, 94.4% specificity, and AUC = 0.942. Agreement between prognostic and observed outcomes was substantial (Cohen's ϰ = 0.84). CONCLUSIONS: The proposed thermal image processing enabled objective assessment of burn depth and facilitated non-invasive monitoring of wound healing. The developed model showed high prognostic performance and substantial agreement with the final clinical outcomes. Further validation in larger prospective cohorts is needed to support the development of standardised protocols.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Digital and Inflammatory Markers of Delayed Healing in Burns, Ulcers, and Hand Reconstruction: A Prospective Cohort Study.Journal of visualized experiments : JoVE · 2026
- Dynamic Infrared Thermography for Quantitative Assessment of Peripheral Microcirculation: Models, Metrics, and Clinical TranslationPhysiological Measurement · 2026
- Standardized Whole-Body Infrared Thermography to Quantify Regional Skin Temperature in Patients with Lung Cancer.Journal of visualized experiments : JoVE · 2026
- Heat for Healing: A Review of Infrared Thermography in Medical Diagnostics and TherapyJournal of Medical Physics · 2026
- UTILITY OF INDOCYANINE GREEN FLUORESCENCE IMAGING IN BURN MANAGEMENT: A SYSTEMATIC REVIEW.Journal of burn care & research : official publication of the American Burn Association · 2026
- Evaluating research-grade and commercial SFDI platforms for burn severity assessment and feature reduction.bioRxiv : the preprint server for biology · 2026