Correlation between free-field cortical auditory evoked potentials and behavioral audiometry thresholds in pediatric patients with hearing aids or cochlear implants.
Yang Ruan, Yuan Wang, Wendi Shi, Fangjun Zhang
Northwest University First Hospital, P.R. China. · Hangzhou Hui'er Hearing Instrument & Technique Co. Ltd., P.R. China.
Key points
From the paper's conclusion- When evaluating the efficiency of hearing interventions in clinical settings, free-field CAEP testing using tone-burst stimuli may serve as a clinically useful supplementary tool for pediatric patients who have difficulty cooperating with behavioral audiometry, provided its limitations are taken into account.
Abstract
OBJECTIVES: To determine the correlation between hearing thresholds obtained using free-field Cortical Auditory Evoked Potentials (CAEPs) and behavioral audiometry in children with sensorineural hearing loss after hearing-aids or cochlear-implant intervention, and to determine whether P1 latency and N1-P1 inter-peak amplitude can be used to assess hearing device outcome in young children. METHODS: Thirty-three children (2-14 years) with mild-to-profound sensorineural hearing loss were divided into a cochlear-implant group (22-ears) and a hearing-aid group (27-ears). Tone burst stimuli at 0.5-, 1-, 2-, and 4-kHz were used to evoke CAEPs and behavioral audiometry thresholds in a free field. The CAEP P1 latency and N1-P1 inter-peak amplitude were recorded. RESULTS: Free-field tone-burst CAEP P1 response thresholds were positively correlated with free-field behavioral audiometry thresholds at 0.5-, 1-, 2-, and 4-kHz in both the hearing-aid group (Pearson correlation coefficients: 0.567, 0.670, 0.637, and 0.762, respectively, p < 0.01) and the cochlear-implant group (0.825, 0.662, 0.538, and 0.567 respectively). At the tested frequencies, the mean differences between the 2 testing methods were 5-8 dB in the cochlear-implants group and 1-6 dB in the hearing-aid group. In both groups, the CAEP P1 latencies were 130-150 ms, and the N1-P1 inter-peak amplitudes were 6 μV. CONCLUSIONS: When evaluating the efficiency of hearing interventions in clinical settings, free-field CAEP testing using tone-burst stimuli may serve as a clinically useful supplementary tool for pediatric patients who have difficulty cooperating with behavioral audiometry, provided its limitations are taken into account. LEVEL OF EVIDENCE: This study is a diagnostic study providing Level 2b evidence. The results demonstrate a significant correlation between CAEP and behavioral hearing thresholds in children using hearing devices, supporting its potential applicable value as an objective clinical assessment tool.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cortical P1 Latency, Sound Field Audiometry, and Speech Audiometry in Children with Sequential Bilateral Cochlear Implants: A Comparative Pilot Study.Journal of clinical medicine · 2026
- Association of AutoART eCAP thresholds with behavioral THR and MCL in pediatric cochlear implant users.Cochlear implants international · 2026
- Reading Abilities and Visual Evoked Potentials in Hearing-Impaired Children: A Comparative Study of Cochlear Implant and Hearing Aid Users.Audiology & neuro-otology · 2026
- Electrically evoked compound action potentials in adult and pediatric cochlear implant users: I. Cochlear nerve responsiveness and electrode-neuron interface index.Hearing research · 2026
- A dual-data-driven approach for predicting cochlear implant dynamic range parameters using neural response telemetry and electrically evoked auditory brainstem response thresholds.Hearing research · 2026
- Using cortical auditory-evoked potential responses to verify the objective benefit of aural rehabilitation in adult cochlear implant users.Frontiers in neuroscience · 2026