Brazilian journal of anesthesiology (Elsevier)

Awake versus deep airway device removal in pediatric tonsillectomy: a systematic review and meta-analysis.

Henrique Baggio Pivetta, Alice O Almeida, Rafael L Miranda, Rafaela P Silva, Raphaela G Mendes, João M M Borges, Raquel E Saldanha, Matheus Arraes,

Universidade do Sul de Santa Catarina, Department of Medicine, Palhoça, SC, Brazil. Electronic address: henriquebpivetta@hotmail.com. · Faculdade de Medicina Zarns, Department of Medicine, Salvador, BA, Brazil.

Meta-analysis

Key points

From the paper's conclusion
  • Deep airway device removal was associated with less coughing, with no evidence that this effect differed between LMA and ETT. Deep removal may increase airway obstruction, though sensitive to individual studies. Desaturation findings were sensitive to study design and sare not definitive.

Abstract

BACKGROUND AND OBJECTIVES: Tonsillectomy, with or without adenoidectomy, is among the most common pediatric surgeries, associated with a high incidence of perioperative respiratory adverse events. The timing of airway device removal, during deep anesthesia or after awakening, may influence these outcomes. METHODS: PubMed, Embase and CENTRAL were systematically searched for studies comparing awake and deep airway device removal in pediatric otolaryngology surgery. The primary analysis was restricted to Randomized Controlled Trials (RCTs). The primary outcome was laryngospasm; secondary outcomes included cough, oxygen desaturation and airway obstruction. Risk Ratios (RR) with 95% Confidence Intervals (95% CI) were pooled using random-effects models. RESULTS: Seven studies (six RCTs and one observational study, the latter used only in sensitivity analyses), including 1,571 children, were analyzed. Deep airway device removal was associated with a higher risk of airway obstruction (RR = 1.82; 95% CI 1.10-3.03; p = 0.020) and a lower risk of cough (RR = 0.57; 95% CI 0.43-0.75; p < 0.001), with no evidence of a difference between the Laryngeal Mask Airway (LMA) and Endotracheal Tube (ETT) subgroups (p for subgroup differences = 0.992). Laryngospasm did not differ significantly (RR = 0.99; 95% CI 0.43-2.30; p = 0.984). Desaturation was lower with deep removal in the RCT-only analysis (RR = 0.62; 95% CI 0.44-0.88; p = 0.007). CONCLUSIONS: Deep airway device removal was associated with less coughing, with no evidence that this effect differed between LMA and ETT. Deep removal may increase airway obstruction, though sensitive to individual studies. Desaturation findings were sensitive to study design and sare not definitive.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers