Patient-reported disability has insufficient clinical accuracy for predicting physical function in survivors of critical illness: a secondary analysis of a cluster-randomised trial.
Nicolas Paul, Elena Ribet, Julius J Grunow, Andreas Edel, Claudia D Spies, Björn Weiss
Department of Anesthesiology and Intensive Care Medicine (CCM/CVK), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany. Electronic address: Nicolas.Paul@charite.de. · Department of Anesthesiology and Intensive Care Medicine (CCM/CVK), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
Key points
From the paper's conclusion- With increasing disability, HGS and 2MWT performance declined, although correlations were moderate and uncertainty of predictions exceeded MCIDs of both instruments. Remote WHODAS 2.0 assessments cannot replace in-person physical function testing.
Abstract
BACKGROUND: Post-ICU care often misses patients unable to attend in-person clinic visits. Remote assessments of physical function might increase access to ICU aftercare. We investigated whether patient-reported disability predicts handgrip strength (HGS) and the 2-Minute Walk Test (2MWT) distance with sufficient clinical accuracy. METHODS: This secondary analysis of the stepped-wedge cluster-randomised Enhanced Recovery after Intensive Care trial included patients from 10 German ICU clusters who completed the WHO Disability Assessment Schedule (WHODAS) 2.0 plus either HGS, the 2MWT, or both, 6 months after ICU discharge. Relationships between WHODAS 2.0, HGS, and 2MWT were analysed using scatter plots, correlation coefficients, linear regressions, and Bland-Altman plots. Predictions of HGS and the 2MWT were compared with the minimal clinically important difference (MCID) for both measures. RESULTS: Of 1463 enrolled patients, 620 were analysed. The median WHODAS 2.0 sum score was 11 (Q1, Q3: 3, 22). The median HGS, expressed as a percentage of the expected value (%exp), was 70.6%exp (Q1, Q3: 54.4, 85.6), and the median 2MWT distance was 73.7%exp (Q1, Q3: 61.5, 85.8). The 2MWT was not completed by 59% of patients. Higher disability was moderately correlated with lower HGS (Spearman %exp: -0.41) and shorter 2MWT distance (Spearman %exp: -0.47). In multivariable regression models, the WHODAS 2.0 sum score predicted HGS in kg (β: -0.27 [95% CI: -0.33 to -0.22]; P<0.001) and 2MWT distance in m (β: -1.94 [95% CI: -2.37 to -1.51]; P<0.001), but the limits of agreement exceeded the MCIDs. CONCLUSIONS: With increasing disability, HGS and 2MWT performance declined, although correlations were moderate and uncertainty of predictions exceeded MCIDs of both instruments. Remote WHODAS 2.0 assessments cannot replace in-person physical function testing. CLINICAL TRIAL REGISTRATION: NCT03671447.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Montafon Proposal: New Insights and Emerging Concepts in Pulmonary Rehabilitation.Respiration; international review of thoracic diseases · 2026
- Clinically interpretable prediction models of stroke functional outcomes: A national cohort study of adults in inpatient rehabilitation facilities in the US.Archives of physical medicine and rehabilitation · 2026
- Low Physical Activity and Reported Barriers Among Survivors of Critical Illness: A Mixed-Method Study.Critical care medicine · 2026
- Routine physiotherapy outcome measures use for acute internal medicine: an implementation study.Disability and rehabilitation · 2026
- Impaired Adult Ventilatory Weaning Response (00430) Undergoing Cardiac Surgery: A Cross-Sectional Study.International journal of nursing knowledge · 2026
- Validation of a markerless motion capture app for automated scoring of sit-to-stand, timed up and go, and short physical performance battery tests in adults with chronic diseasePLOS Digital Health · 2026