Biosensors & bioelectronics

A practical electrochemical aptasensor platform via a label-free strand-displacement strategy for saxitoxin detection in real samples.

Tingting Liu, Bicheng Zhu, Yitong Tseo, John R D Hervey, Jadranka Travas-Sejdic

Centre for Innovative Materials for Health, School of Chemical Sciences, University of Auckland, 23 Symonds Street, Auckland, 1010, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, PO Box 600, Wellington, 6140, New Zealand. · Department of Computational and Systems Biology, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.

Key points

From the paper's conclusion
  • Consequently, the developed aptasensor demonstrated excellent analytical performance, featuring a wide linear range (0.1 nM to 1.0 μM) and a low calculated limit of detection (102.7 pM), alongside outstanding selectivity, stability and reproducibility.

Abstract

Accurate detection of saxitoxin (STX) in marine ecosystems remains severely hindered by matrix interference, demanding robust and reliable sensing platforms. Herein, we report a label-free electrochemical aptasensor for sensitive STX detection based on a target-induced strand displacement and competitive hybridisation strategy. Utilizing a terminal-hairpin aptamer for selective target recognition triggers the release of a signaling oligonucleotide (ON1), which subsequently hybridises with a complementary capture probe (ON2) immobilised on a gold nanoparticle-modified electrode. This design enables efficient signal transduction without exogenous labels or amplification steps. Molecular docking simulations confirmed the specific binding of the aptamer toward STX. Consequently, the developed aptasensor demonstrated excellent analytical performance, featuring a wide linear range (0.1 nM to 1.0 μM) and a low calculated limit of detection (102.7 pM), alongside outstanding selectivity, stability and reproducibility. Crucially, beyond standard spike-and-recovery validations in seawater (80.4%-108.0%) and blank Greenshell mussel (GSM) matrix (106.1%-117.8%), this platform was successfully deployed for the direct determination of STX in authentic, field-collected toxic GSM extracts caused by different algal bloom events (82.4%-118.2%). As one of the pioneering demonstrations validated with naturally contaminated samples, this strategy underscores superior matrix tolerance and offers a generalizable framework for routine marine surveillance and regulatory food safety screening.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers