Electrochemical detection of levodopa via integrated molecularly imprinted recognition and tyrosinase catalysis on MOF-derived CuCo@N-doped carbon nanosheet arrays/3D graphene foam.
Haopeng Zhang, Shuo Huang, Huaze Sun, Haiyang Li, Hongyan Yue
School of Materials Science and Chemical Engineering, Harbin University of Science and Technology, Harbin, 150040, People's Republic of China. · Department of Neurology, First Affiliated Hospital of Harbin Medical University, Harbin, 150001, People's Republic of China.
Key points
From the paper's conclusion- First, CuCo-ZIF nanosheet arrays are grown in situ on three-dimensional graphene foam (3D GF) and converted into Cu/Co nanoparticle anchored N-doped carbon nanosheet arrays (CuCo@NCNSA/3D GF) by pyrolysis.
Abstract
Levodopa (LD) is a primary therapeutic agent for Parkinson's disease, and accurately monitoring its concentration in blood is crucial for optimizing treatment regimens. Herein, an electrochemical sensing electrode integrating molecular imprinting with tyrosinase (TYR) catalysis is developed for sensitive and selective LD detection. First, CuCo-ZIF nanosheet arrays are grown in situ on three-dimensional graphene foam (3D GF) and converted into Cu/Co nanoparticle anchored N-doped carbon nanosheet arrays (CuCo@NCNSA/3D GF) by pyrolysis. Subsequently, a molecularly imprinted poly(3,4-ethylenedioxythiophene) (MI-PEDOT) layer is electropolymerized using LD as the template, followed by covalent immobilization of TYR. The electrode integrates the molecular recognition capabilities and electrochemical activity of MI-PEDOT with the enzymatic catalysis of TYR, achieving a sensitivity of 2.059 μA μM-1 and a limit of detection (LOD) of 0.016 μM for LD. In 50-fold and 100-fold diluted serum samples, LODs are 0.31 and 0.10 μM, respectively. For whole blood analysis, a polyacrylamide hydrogel (PAM-H) antifouling layer enables direct whole blood filtration, allowing quantitative LD detection over the range of 0-20 μM with a LOD of 1.0 μM. The PAM-H-assisted electrode maintains a stable response and enables reliable LD quantification in whole blood filtrates, highlighting their potential for the rapid analysis of complex biological samples and for use in point-of-care testing (POCT).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cu/Cu2O-embedded carbon from Cu-MOF integrated with MWCNTs-COOH for sensitive levodopa detection in biological samples.Colloids and surfaces. B, Biointerfaces · 2026
- A nanoMIP sensor for real-time in vivo monitoring of levodopa pharmacokinetics in precision Parkinson’s therapyNature Communications · 2025
- Dual-form iron on carbon nanohorns for wide-pH-range electrochemical sensing of levodopa.Mikrochimica acta · 2026
- Rational Design of Au@co-MOF Synergistic Platform for Ultrasensitive Monitoring of Dopamine in Human Biological Fluids.ACS omega · 2026
- A portable smartphone-integrated chiral molecularly imprinted electrochemical sensing platform based on L-histidine-functionalized Q-HKUST/PEDOT for highly selective detection of L-tyrosine.Talanta · 2026
- Microneedle-Based Continuous Levodopa Monitoring in Patients with Parkinson's Disease.ACS sensors · 2026