Biosensors & bioelectronics

Thin film conductors for single-molecule, label-free detection using resistive pulse sensing.

Quentin Jarrell, Pubudu Premarathne, Randy F Espinal Cabarera, Farhad Shiri, Collin McKinney, Steven A Soper

Bioengineering Program, The University of Kansas, Lawrence, KS, 66045, USA; Center of Biomodular Multiscale Systems for Precision Medicine, USA. · Center of Biomodular Multiscale Systems for Precision Medicine, USA; Department of Chemistry, The University of Kansas, Lawrence, KS, 66045, USA.

Key points

From the paper's conclusion
  • Here, we present a monolithic integration approach for patterning thin film Ag/AgCl electrodes to a hybrid cyclic olefin polymer/copolymer (COP/COC) fluidic sensor.

Abstract

Resistive Pulse Sensing (RPS) provides a label-free detection of single-molecules; however, conventional RPS systems that rely on macroscopic wire electrodes suffer from mechanical instability and positional drift, which can contribute to large amounts of low-frequency noise. Integrating thin-film electrodes into RPS devices can address these issues, especially when coupled to devices that use thermoplastic substrates due to their ability to be fabricated in a high production mode. However, thin metal films patterned on polymer surfaces are limited by polymer surface energy mismatches and thermal deformation during metallization and bonding. Here, we present a monolithic integration approach for patterning thin film Ag/AgCl electrodes to a hybrid cyclic olefin polymer/copolymer (COP/COC) fluidic sensor. Robust interfacial adhesion was achieved utilizing O2 plasma pretreatment of the plastic and a Titanium (Ti) adhesion layer followed by pulsed DC magnetron sputtering. A thermal fusion bonding protocol mitigated electrode step-height standoff, ensuring hermetic sealing without compromising the integrity of the sub-100 nm features patterned via replication into the plastic substrate. Electrochemical characterization confirmed stable, non-polarizable operation for >3 h, while power spectral density (PSD) analysis demonstrated reduced 1/f noise compared to wire electrodes. During the translocation of a 1200 nt DNA through an in-plane nanopore (diameter ∼10 nm), the integrated device delivered a 3.3-fold enhancement in the Signal-to-Noise Ratio (SNR) compared to macro-scale wire electrodes. This performance was driven by a suppressed RMS noise floor and a 2.9-fold increase in fractional blockade amplitude. This work establishes a scalable, high-yield fabrication framework for robust, high-sensitivity solid-state nanopore sensing platforms.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Thin film conductors for single-molecule, label-free detection using resistive pulse sensing — Science Skim