Biosensors & bioelectronics

N-heterocyclic engineering of covalent organic framework (COF)-microenvironments for the development of enzyme-based biosensor with application to lung cancer diagnosis.

Tianci Zhou, Zhiyue Wang, Ying Deng, Yu Sun, Man Xue, Bing Bo, Zhaoxia Wang, Genxi Li

State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing, 210023, PR China. · Department of Oncology, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, 210011, PR China.

Key points

From the paper's conclusion
  • Experimental results reveal that the biosensor can exhibit a broad linear range and achieve a limit of detection (LOD) as low as 4 particles/μL.

Abstract

Maintenance and enhancement of the catalytic activity of natural enzymes remain challenging in the development of high-performance enzyme-based biosensors. In this work, we propose a rational ligand-engineering strategy for constructing enzyme@covalent organic framework (COF) composites by integrating nitrogen heterocyclic microenvironment regulation with a deep eutectic solvent (DES)-assisted mild synthesis approach for the enhancement of enzyme activity. Furthermore, a high-performance biosensor is fabricated for the detection of non-small cell lung cancer (NSCLC)-derived exosomes. Specifically, the incorporation of nitrogen-rich ligands into COF frameworks may create an electron-rich hydrogen-bonding microenvironment under biocompatible conditions provided by DES for rapid in situ growth of COFs. Enzyme kinetic analysis demonstrates that the introduction of nitrogen-heterocyclic ligands can effectively enhance enzymatic catalytic efficiency, and spectroscopic analyses further confirm the conformation changes in the enzyme caused by the introduction of the nitrogen-containing ligands. Consequently, a high-performance electrochemical biosensor is fabricated based on the enzyme@COF composites for the detection of NSCLC-derived exosomes. Experimental results reveal that the biosensor can exhibit a broad linear range and achieve a limit of detection (LOD) as low as 4 particles/μL. Moreover, clinical sample analysis confirms its capability to accurately discriminate NSCLC patients from healthy individuals.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

N-heterocyclic engineering of covalent organic framework (COF)-microenvironments for the development of enzyme-based biosensor with application to lung cancer diagnosis — Science Skim