NanoMIP-embedded metal-phenolic networks as an advanced electrochemical platform for the ultrasensitive detection of PFOA and PFOS in water.
Perrine Lasserre, Nozomi Matsudaira, Tobias Hrovat, Amy Q Shen, Mark V Sullivan
Micro/Bio/Nanofluidics, Okinawa Institute of Science and Technology Graduate University, 1919-1 Tancha, Onna-son, Okinawa, 904-0495, Japan. · Micro/Bio/Nanofluidics, Okinawa Institute of Science and Technology Graduate University, 1919-1 Tancha, Onna-son, Okinawa, 904-0495, Japan. Electronic address: amy.shen@oist.jp.
Key points
From the paper's conclusion- Here, we report a nanoMIP-metal-phenolic network (MPN) electrochemical sensing platform for highly sensitive detection of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) in water samples.
Abstract
Per- and polyfluoroalkyl substances (PFAS) are persistent synthetic fluorinated contaminants that require rapid, sensitive, and field-deployable analytical technologies beyond conventional laboratory-based mass spectrometry. Here, we report a nanoMIP-metal-phenolic network (MPN) electrochemical sensing platform for highly sensitive detection of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) in water samples. PFOA- and PFOS-specific molecularly imprinted polymer nanoparticles (nanoMIPs) were synthesised by scalable suspension polymerisation, yielding high-affinity synthetic receptors with equilibrium dissociation constants of KD = 3.80 nM for PFOA and KD = 2.76 nM for PFOS. The nanoMIPs were immobilised onto flexible screen-printed electrodes through a redox-active MPN containing an embedded electrochemical mediator, creating an integrated recognition-and-transduction interface. PFAS rebinding within the nanoMIP layer restricted interfacial charge transfer, producing a concentration-dependent differential pulse voltammetry response without externally added redox probes. The platform detected PFOA and PFOS over 1-100 pg mL-1, with limits of detection of 1.11 pg mL-1 and 1.63 pg mL-1, respectively. Strong molecular discrimination was demonstrated against structurally related PFAS homologues, including perfluorohexanoic acid (PFHxA) and perfluorodecanoic acid (PFDA), as well as chemically distinct non-target compounds. Quantification in drinking water and freshwater samples yielded recoveries of 88-96%. By combining scalable nanoMIP synthesis, redox-active interfacial engineering, and flexible electrode fabrication, this work establishes a practical platform for portable PFAS monitoring and broader environmental sensing applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The electroanalytical wave against forever chemicals: molecularly imprinted electrochemical sensors for PFAS detection.Chemical communications (Cambridge, England) · 2026
- Ratiometric detection of perfluoroalkyl carboxylic acids using dual fluorescent nanoparticles and a miniaturised microfluidic platformNature Communications · 2025
- Surface-initiated molecularly imprinted polymer film for sensitive electrochemical detection of PFOA in environmental waters.Mikrochimica acta · 2026
- A ferrocene-integrated fluorinated molecularly imprinted sensor for external-probe-free and portable PFOA detection.Journal of hazardous materials · 2026
- Multi-affinity electrochemical perfluorooctanoic acid sensing enabled by a microenvironment-engineered MOF synergy.Chemical science · 2026
- Electrochemical Detection of Perfluorooctane Sulfonate in Water Using a Metal‐Organic Framework‐Modified ElectrodeAnalysis & Sensing · 2026