Biosensors & bioelectronics

NanoMIP-embedded metal-phenolic networks as an advanced electrochemical platform for the ultrasensitive detection of PFOA and PFOS in water.

Perrine Lasserre, Nozomi Matsudaira, Tobias Hrovat, Amy Q Shen, Mark V Sullivan

Micro/Bio/Nanofluidics, Okinawa Institute of Science and Technology Graduate University, 1919-1 Tancha, Onna-son, Okinawa, 904-0495, Japan. · Micro/Bio/Nanofluidics, Okinawa Institute of Science and Technology Graduate University, 1919-1 Tancha, Onna-son, Okinawa, 904-0495, Japan. Electronic address: amy.shen@oist.jp.

Key points

From the paper's conclusion
  • Here, we report a nanoMIP-metal-phenolic network (MPN) electrochemical sensing platform for highly sensitive detection of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) in water samples.

Abstract

Per- and polyfluoroalkyl substances (PFAS) are persistent synthetic fluorinated contaminants that require rapid, sensitive, and field-deployable analytical technologies beyond conventional laboratory-based mass spectrometry. Here, we report a nanoMIP-metal-phenolic network (MPN) electrochemical sensing platform for highly sensitive detection of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) in water samples. PFOA- and PFOS-specific molecularly imprinted polymer nanoparticles (nanoMIPs) were synthesised by scalable suspension polymerisation, yielding high-affinity synthetic receptors with equilibrium dissociation constants of KD = 3.80 nM for PFOA and KD = 2.76 nM for PFOS. The nanoMIPs were immobilised onto flexible screen-printed electrodes through a redox-active MPN containing an embedded electrochemical mediator, creating an integrated recognition-and-transduction interface. PFAS rebinding within the nanoMIP layer restricted interfacial charge transfer, producing a concentration-dependent differential pulse voltammetry response without externally added redox probes. The platform detected PFOA and PFOS over 1-100 pg mL-1, with limits of detection of 1.11 pg mL-1 and 1.63 pg mL-1, respectively. Strong molecular discrimination was demonstrated against structurally related PFAS homologues, including perfluorohexanoic acid (PFHxA) and perfluorodecanoic acid (PFDA), as well as chemically distinct non-target compounds. Quantification in drinking water and freshwater samples yielded recoveries of 88-96%. By combining scalable nanoMIP synthesis, redox-active interfacial engineering, and flexible electrode fabrication, this work establishes a practical platform for portable PFAS monitoring and broader environmental sensing applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers