Low-potential ciprofloxacin detection in wound exudate via docking-guided molecular imprinting and redox-active reporter transduction.
Dingxi Lu, Bingxuan Wang, Jie Fu, Lizhi Lin, Uul Gegeen, Wen Pan, Fanyu Mu, Yihong Ding,
Academy of Medical Engineering and Translational Medicine, Medical School, Tianjin University, Tianjin, 300072, China. · Academy of Medical Engineering and Translational Medicine, Medical School, Tianjin University, Tianjin, 300072, China. Electronic address: lishuangv@tju.edu.cn.
Key points
From the paper's conclusion- Here, we developed a redox-active reporter-mediated molecularly imprinted electrochemical sensor (RAR-MIECS) for low-potential CIP quantification across non-infected and infected wound microenvironments.
Abstract
Accurate quantification of ciprofloxacin (CIP) in wound exudate is important for assessing local antibiotic exposure and supporting rational wound infection management. However, direct electrooxidation of CIP requires a high working potential and is susceptible to interference from endogenous electroactive species in complex wound matrices. Here, we developed a redox-active reporter-mediated molecularly imprinted electrochemical sensor (RAR-MIECS) for low-potential CIP quantification across non-infected and infected wound microenvironments. Moldina-assisted multiple-ligand docking guided the construction of a dual-monomer imprinted interface composed of 3-aminophenylboronic acid and pyrrole for selective CIP recognition. Stepwise electrodeposition of RAR films converted CIP rebinding-induced interfacial blocking into a signal-off response near 0 V. Compared with direct CIP electrooxidation, RAR-mediated transduction shifted the operating potential window by approximately 0.7 V toward negative potentials and increased the current difference by approximately 10-fold. Because distinct differential pulse voltammetric responses were observed in simulated non-infected and infected wound fluids, microenvironment-matched calibration relationships were established at pH 6.5 and 7.4. The RAR-MIECS showed linear responses over 0.001-100 μM in both media, with detection limits of 0.142 and 0.126 nM, respectively, together with good selectivity, interference resistance, reproducibility, and stability. Spike-recovery analysis in murine wound exudate samples yielded recoveries of 98.0%-106.0% for 5-20 μM CIP, with relative standard deviations below 7%. This microenvironment-matched platform provides a low-interference strategy for reliable CIP quantification in complex wound-exudate matrices and offers an analytical basis for future concentration-guided anti-infective wound management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-cleaning and recyclable magnetic MIP-SERS sensor based on ZnFe2O4-Cu2O-Au@Ag nanocomposites for ultrasensitive and selective detection of ciprofloxacin.Talanta · 2026
- Regulation of Template Ionization and Template-Monomer Interactions for Enhanced Molecular Imprinting and Selective Detection of Promethazine.Polymers · 2026
- A Synergistic Experimental and Computational Approach to the Design of MIPs Targeting Metronidazole.Analytical chemistry · 2026
- Interlayer-confined redox in Ti₃C₂Tₓ-MXene laminates: a reagent-free screen-printed platform for the detection of erdafitinibMicrochimica Acta · 2026
- Visible light-mediated synthesis of metal-free molecularly imprinted polymers for highly selective creatinine detection.International journal of biological macromolecules · 2026
- Transition-frequency dielectrophoresis for antibiotic detection through binding-induced interfacial charge modulation.Biosensors & bioelectronics · 2026