Biosensors & bioelectronics

Label-free electrical detection of salivary extracellular vesicles using an anti-CD63-functionalized gold extended-gate field-effect transistor.

Ajitesh Dhal, Ana Elena Aviña, Cheng-Jen Chang, Chang-I Chen, Pei-Wen Peng, Chih-Yuan Fang, Tzu-Sen Yang

International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, New Taipei City, 235603, Taiwan; Graduate Institute of Biomedical Optomechatronics, Taipei Medical University, Taipei, 110, Taiwan. · Graduate Institute of Biomedical Optomechatronics, Taipei Medical University, Taipei, 110, Taiwan; International Ph.D. Program in Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan; Division of Plastic Surgery, Department of Surgery, Taipei Medical University Hospital, Taipei, 110, Taiwan.

Key points

From the paper's conclusion
  • Here a label-free gold extended-gate field-effect transistor (EG-FET) functionalized with an antibody that binds specifically to the Cluster of Differentiation 63 (anti-CD63), was developed for electrical detection of isolated salivary sEVs.

Abstract

Salivary extracellular vesicles (sEVs) are accessible candidates for non-invasive biomarker analysis, but their measurement commonly requires multistep, label-dependent workflows. Here a label-free gold extended-gate field-effect transistor (EG-FET) functionalized with an antibody that binds specifically to the Cluster of Differentiation 63 (anti-CD63), was developed for electrical detection of isolated salivary sEVs. Gold gates were modified with an 11-mercaptoundecanoic acid self-assembled monolayer and [1-Ethyl-3-(3-Dimethylaminopropyl) carbodiimide/N-Hydroxysuccinimide] EDC/NHS-mediated antibody immobilization. Binding-induced changes were quantified as the ratio of areas under transfer curves (AUC) acquired before and after incubation. Inter-chip coefficient of variation decreased from 10.5% for bare gates to 1.5% after antibody immobilization. The AUC ratio decreased with sEV concentration across 0.01X-1X (R2 = 0.980); using the blank mean minus three standard deviations, the estimated detection threshold was approximately 0.1X (about 9.8 × 107 particles/mL for the representative stock). Anti-CD63 gates exposed to 0.1X sEVs produced a significant response, whereas Phosphate-Buffered Saline (PBS), Bovine Serum Albumin (BSA), and heterologous-antibody controls remained near baseline. Four independent sessions across a 16-day interval yielded coefficients of variation of 1.4% for PBS and 1.7% for sEV measurements. Response was retained when isolated sEVs were spiked into 0.2X clarified saliva. These proof-of-concept findings support reproducible label-free sEV detection while defining the need for direct whole-saliva interference testing, storage studies, and validation in clinically characterized cohorts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers