Universal contamination-free nucleic acid biosensing enabled by guide-independent Argonaute amplicon elimination.

Jinyi Shi, Sheng Ding, Feng Du, Juan Dong, Sifan Wang, Kaiyuan Ren, Jing Li, Haiyan Li, Chengze Wu, Song Zhao, Xijun Yang, Fei Wang, Wei Wang, Rong Chen, Xin Cui, Zhuo Tang

原始摘要(英文原文)· Original abstract
Amplicon contamination remains a major challenge in nucleic acid biosensing, frequently compromising diagnostic accuracy in both clinical testing and field-deployable sensing systems. Although strategies such as uracil-DNA glycosylase (UDG) treatment and CRISPR-based approaches have been developed to mitigate this problem, their broader implementation is often limited by incomplete decontamination, increased assay cost, and the complexity associated with exogenous guide design. Here we introduce CREDIT (chopping-based Argonaute-mediated testing), a molecular diagnostic biosensor platform that harnesses the intrinsic chopping activity of Pyrococcus furiosus Argonaute (PfAgo). Unlike conventional Argonaute-based biosensing assays that primarily use Argonaute as a signal-generating enzyme, CREDIT operates as a dual-function system: it degrades amplification products into short fragments that are inert to further amplification, while simultaneously repurposing these chopping-derived fragments as guides to direct sequence-specific cleavage of reporter probes for signal generation. We demonstrate that this integrated detect-and-destroy mechanism enables seamless coupling of CREDIT with both PCR and isothermal amplification for ultrasensitive nucleic acid detection. The platform preserves the attomolar sensitivity of the amplification-based assay without compromising assay speed. Notably, a stringent 20-round consecutive open-lid stress test confirms complete suppression of amplicon contamination, thereby enabling uncapped post-amplification handling for lateral flow strip (LFS) sensor readout-an operation previously considered unsafe in field-deployable molecular testing. Together, these results establish CREDIT as a contamination-resistant biosensing strategy for molecular diagnostics that enables reliable and consecutive nucleic acid detection, particularly in resource-limited settings.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Universal contamination-free nucleic acid biosensing enabled by guide-independent Argonaute amplicon elimination. — 科研速览 Science Skim