Bioorganic chemistry

A Dual-Channel fluorescent probe for HClO detection with differential distribution of cleavage products in lysosomes and mitochondria and time-dependent imaging of hepatic ischemia-reperfusion injury.

Likun Liu, Junqiang Liu, Yu Zhao, Song Chen, Xue Zhang, Bo Wang, Rongxin Jin, Haoqing Ren,

Department of Scientific Research, Qiqihar Medical University, Qiqihar 161006, PR China. · College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China.

Key points

From the paper's conclusion
  • Collectively, NDI-OX provides a versatile analytical platform integrating sensitive HClO detection, dual-channel readout of cleavage-product distribution, and time-dependent visualization of oxidative injury.

Abstract

Hypochlorous acid (HClO) is a highly reactive chlorine species implicated in environmental contamination and oxidative stress-associated pathological processes. Herein, we developed NDI-OX, a dual-channel fluorescent probe for sensitive HClO detection and visualization of HClO-associated oxidative injury. HClO-triggered cleavage of NDI-OX simultaneously generated well-separated fluorescence emissions at 537 and 670 nm, enabling rapid (< 2 min), selective, and sensitive detection with limits of detection of 21.4 and 13.2 nM, respectively. NDI-OX also enabled spike-recovery analysis of HClO in tap and river water samples, affording recoveries of 96.1-104.3%. Notably, the two HClO-responsive fluorescence signals exhibited a differential distribution of the released cleavage products, with the green and red/far-red channels preferentially accumulating in lysosomal and mitochondrial regions, respectively, enabling dual-channel readout of HClO-associated oxidative processes. It should be noted that this readout reflects the distribution of the released products rather than the exact site of HClO reaction. Furthermore, NDI-OX monitored relative changes in HClO-associated oxidative stress during hepatic ischemia-reperfusion injury (HIRI) and enabled fluorescence-based evaluation of hepatoprotective interventions. Collectively, NDI-OX provides a versatile analytical platform integrating sensitive HClO detection, dual-channel readout of cleavage-product distribution, and time-dependent visualization of oxidative injury.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Dual-Channel fluorescent probe for HClO detection with differential distribution of cleavage products in lysosomes and mitochondria and time-dependent imaging of hepatic ischemia-reperfusion injury — Science Skim