Catalytic MXene implant interfaces reprogram radiation-induced foreign body response to prevent capsular contracture.
Yusi Zhang, Zhongxue Lin, Yifan Qiao, Qianqian Yang, Min Chen, Danfeng Dong, Gengrui Nan, Zihuan Wei,
Department of Medical Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi, 710061, PR China; Department of Cancer Center, The First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi, 710061, PR China; Precision Medicine Center, The First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi, 710061, PR China. · The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Shaanxi, 710061, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Shaanxi, 710061, PR China.
Key points
From the paper's conclusion- Collectively, these findings demonstrate that MXene-based catalytic coatings can disrupt the positive feedback loop between radiation injury and fibrotic capsule formation, offering a mechanistically grounded strategy to mitigate implant-associated fibrosis.
Abstract
Radiotherapy markedly exacerbates foreign body response (FBR) to silicone implants, driving capsular fibrosis and contracture, yet actionable interfacial mechanisms remain insufficiently defined. Here, we engineer an implant-centered Ti3C2Tx MXene-modified PDMS coating (APM) to modulate the redox microenvironment at the tissue-implant interface to reprogram radiotherapy-induced FBR. Oxygen plasma activation and 3-aminopropyltriethoxysilane (APTES) silanization enable covalent anchoring of single-layer MXene nanosheets onto PDMS, yielding a conformal APM film with enhanced hydrophilicity, preserved layered MXene architecture, enzyme-mimicking ROS-scavenging activity, and excellent cytocompatibility. Transcriptomic profiling guides the study, revealing the coordinated downregulation of inflammatory and extracellular matrix remodeling pathways. Mechanistically, interfacial redox regulation dampens NF-κB signaling and reduces endothelial ICAM-1 expression, thereby limiting monocyte adhesion and downstream inflammatory amplification. A tri-culture endothelial-macrophage-fibroblast model further demonstrates that MXene interfaces disrupt pro-inflammatory crosstalk and inhibit myofibroblast activation. In a murine peri-implant irradiation model, APM-coated implants preserve a CD31+/ICAM-1-low microvasculature, reduce peri-implant pro-inflammatory macrophage accumulation, and significantly decrease capsular thickness and collagen deposition. Collectively, these findings demonstrate that MXene-based catalytic coatings can disrupt the positive feedback loop between radiation injury and fibrotic capsule formation, offering a mechanistically grounded strategy to mitigate implant-associated fibrosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sprayable MXene Hydrogels With Composition‐Driven Interfacial Stabilization and on‐Skin Gelation for Conformal Postsurgical Photothermal TherapySmall · 2026
- Nano-Armor Empowers Mesenchymal Stem Cells to Actively Target and Reverse Synovial Inflammation in Rheumatoid Arthritis.Acta biomaterialia · 2026
- Precise control of external stimulus-responsive MXenes for biomedical applicationsCoordination Chemistry Reviews · 2026
- MXene-integrated microneedles reprogram diabetic-associated macrophages for deep-wound infection therapy and immunoprotectionJournal of Nanobiotechnology · 2025
- Surface Engineering of MXenes for Biomedical Uses: Functionalization Strategies and Application TrendsBiomaterials Research · 2026
- Multifunctional scaffold based on Ti3C2Tx/PCL nanofibers composite hydrogel directs myogenic differentiation and microenvironment remodeling for volumetric muscle lossMaterials Today Bio · 2026