Bioelectrochemistry (Amsterdam, Netherlands)

Optimizing electron supply for trichloroethylene reductive dechlorination in a membrane-less bioelectrochemical reactor: Galvanostatic versus potentiostatic approach.

Geremia Sassetto, Angela Marchetti, Marco Petrangeli Papini, Marco Zeppilli

Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 5, 00185, Rome, Italy. · Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro, 5, 00185, Rome, Italy. Electronic address: marco.zeppilli@uniroma1.it.

Key points

From the paper's conclusion
  • In Phase I, shifting from potentiostatic (-450 mV vs SHE) to galvanostatic polarization at -1 mA the coulombic efficiency for reductive dechlorination increased from 0.9 to 31.3% while maintaining complete TCE removal; additionally, the specific energy consumption decreased from 0.61 to 0.001 kWh m-3.

Abstract

This study evaluated galvanostatic control as an alternative to conventional potentiostatic operation for stimulating trichloroethylene (TCE) reductive dechlorination in a bioelectrochemical reactor. A long-term study has been conducted to validate the galvanostatic strategy using a model medium (Phase I) and in presence of competing electron acceptors, i.e. nitrate and sulfate (Phase II). In Phase I, shifting from potentiostatic (-450 mV vs SHE) to galvanostatic polarization at -1 mA the coulombic efficiency for reductive dechlorination increased from 0.9 to 31.3% while maintaining complete TCE removal; additionally, the specific energy consumption decreased from 0.61 to 0.001 kWh m-3. In Phase II, nitrate and sulfate markedly increased the redox demand, indeed, by applying -1 mA to the process, the reductive dechlorination pathway was almost suppressed, whereas -5 mA maintained complete TCE removal and significant dechlorination rate of 40.1 ± 3.2 μeq L-1 d-1. Potentiostatic operation at -450 mV vs SHE during Phase II restored complete TCE dechlorination but required the highest energy consumption (4.0 kWh m-3). The experimental results suggested that the galvanostatic approach is an effective strategy to select microbial metabolisms through the control of hydrogen concentration promoting the activity of dehalogenating microorganisms while suppressing parasitic reactions such as sulfate reduction.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Optimizing electron supply for trichloroethylene reductive dechlorination in a membrane-less bioelectrochemical reactor: Galvanostatic versus potentiostatic approach — Science Skim