Bioelectrochemistry (Amsterdam, Netherlands)

Au-Pd-rGO nanocomposite-based Impedimetric biosensor integrated with spiral microfluidics for hydrodynamic enrichment and detection of colorectal cancer cells.

Debashree Ghosh, Namita Jaiswal, Chandan Har, Soumen Mandal, Soumen Sen, Nripen Chanda

Human Centered Robotics and Cybernetics Group, CSIR - Central Mechanical Engineering Research Institute (CMERI), Durgapur 713209, West Bengal, India.; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, Uttar Pradesh, India. · Human Centered Robotics and Cybernetics Group, CSIR - Central Mechanical Engineering Research Institute (CMERI), Durgapur 713209, West Bengal, India.. Electronic address: namita.dgp@gmail.com.

Key points

From the paper's conclusion
  • Here, we present an integrated microfluidic-electrochemical platform combining spiral microfluidic preconcentration strategy with affinity-mediated impedimetric detection of colorectal cancer cells using an Au-Pd-rGO nanocomposite-based biosensor.

Abstract

The integration of an electrochemical biosensor with a hydrodynamic spiral microfluidic preconcentrator provides a compact platform for cell enrichment, affinity capture, and electrochemical detection of colorectal cancer cells. Here, we present an integrated microfluidic-electrochemical platform combining spiral microfluidic preconcentration strategy with affinity-mediated impedimetric detection of colorectal cancer cells using an Au-Pd-rGO nanocomposite-based biosensor. The sensing interface comprises a screen-printed electrode modified with a bimetallic Au-Pd-rGO nanocomposite, exhibiting a low charge-transfer resistance (Rct ≈ 140 Ω), enhanced electron-transfer kinetics, and a heterogeneous electron-transfer rate constant (k0) of 1.88 × 10-2 cm s-1. Formation of a mixed mPEG-SH/11-MUA layer followed by anti- Epithelial Cell Adhesion Molecule (EpCAM) antibody immobilization increased Rct and decreased ko by approximately 16-fold, confirming formation of the biofunctionalized electrode interface. Affinity capture of HCT116 colorectal cancer cells produced a concentration-dependent increase in Rct over the experimentally evaluated range of 1 × 102-1 × 106 cells mL-1. An analytical limit of detection of approximately 2-3 cells mL-1 was estimated from the calibration statistics. For whole-blood analysis, the spiral microchannel was operated at a total flow rate of 1.0 mL min-1, corresponding to Reynolds and Dean numbers of approximately 48 and 5.7, respectively, enabling hydrodynamic preconcentration of HCT116 cells. Following microfluidic enrichment, the Au-Pd-rGO biosensor generated measurable impedimetric responses for HCT116 cells spiked into diluted healthy-donor whole blood. These results demonstrate an integrated electrochemical-microfluidic strategy in which hydrodynamic enrichment, affinity-mediated cell capture, and impedance-based transduction are coupled within a compact platform, providing a promising basis for future liquid-biopsy and point-of-care cancer detection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers