Sensitive electrochemical detection of Escherichia coli using an aptasensor based on graphene oxide and Prussian blue nanostructures.
Hafezeh Morsalpour, Hamid R Zare, Zahra Shekari, Maryam Sadat Mirbagheri-Firoozabad
Department of Chemistry, Yazd University, Yazd 89195-741, Iran. · Department of Chemistry, Yazd University, Yazd 89195-741, Iran. Electronic address: hrzare@yazd.ac.ir.
Key points
From the paper's conclusion- A label-based electrochemical aptasensor was developed for the selective and sensitive detection of Escherichia coli (E. coli) using a graphene oxide/Prussian blue (GO-PB) nanocomposite as the sensing substrate.
Abstract
A label-based electrochemical aptasensor was developed for the selective and sensitive detection of Escherichia coli (E. coli) using a graphene oxide/Prussian blue (GO-PB) nanocomposite as the sensing substrate. The aptamer sequence specific to E. coli was immobilized on the modified electrode, acting as the biorecognition probe. The electrochemical oxidation current of PB served as the signal label for the quantitative detection of E. coli. The morphology and structure of the GO-PB nanocomposite were confirmed using field emission scanning electron microscopy and Fourier-transform infrared spectroscopy. Under optimized conditions, the aptasensor achieved a limit of detection of 4.1 CFU mL-1 and a linear concentration range from 15.0 to 1.5 × 106 CFU mL-1. The developed aptasensor was successfully applied to the detection of E. coli in real water and milk samples, demonstrating its good reliability and applicability for environmental monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a modified graphene oxide-alginate electrochemical impedance aptasensor for rapid E. coli detectionMicrochemical Journal · 2026
- An aptamer-functionalized AuNPs/rGO nanocomposite biosensor for ultrasensitive detection of foodborne pathogen E. coli O157:H7Scientific Reports · 2026
- Potentiometric aptasensor based on electrodeposition of Au nanoparticles on infinite coordination polymer network for rapid detection of Escherichia coli O157:H7.Mikrochimica acta · 2026
- Design of La@ZnO/AuNPs/GO nanocomposites as an electrochemical sensor for acetaminophen detectionSensing and Bio-Sensing Research · 2025
- High-performance electrochemical biosensor comprising Mn-ZIF-67 conjugated with anti-O antibody for Escherichia coli detectionCommunications Chemistry · 2025
- A Monolithic, Thiol-Functionalized Au-Based Bio-CMOS Aptasensor for Rapid, Label-Free Detection of Escherichia coli O157:H7 in Patient-Derived and Hospital-Acquired Specimens.Bioengineering (Basel, Switzerland) · 2026