Bioelectrochemistry (Amsterdam, Netherlands)

Ferrocene-metal organic framework as a multifunctional electroactive bio-interface for immunosensing of lactoferrin in biomedical applications.

Ayesha Tahira, Ayaz Hassan, Idriss Bakas, Muhammad Shoaib Butt, Farhat Jubeen, Huma Ajab, Ejaz Hussain, Essam R I Mahmoud,

Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus, 1.5 Km Defense Road, off Raiwind Road, Lahore, Punjab, Pakistan 54000; Department of Chemistry, Government College University, Lahore, Pakistan. · Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus, 1.5 Km Defense Road, off Raiwind Road, Lahore, Punjab, Pakistan 54000.

Key points

From the paper's conclusion
  • The practical applicability of GPE/Fe-CM-β-CD-MOF/EDC-NHS/anti-LF antibody biosensor was demonstrated by detection of LF in milk and saliva samples, and good recovery values (98.0-102.0%) were obtained.

Abstract

Lactoferrin (LF) is an iron binding glycoprotein, whose accurate quantification is increasingly significant for health and food safety monitoring. Herein, an advanced electrochemical bioelectrode based on ferrocene-incorporated carboxymethyl-β-cyclodextrin metal-organic framework (Fe-CM-β-CDMOF) is synthesized for sensitive lactoferrin detection. The synergistic properties of CM-β-cyclodextrin and trimesic acid (BTC) produce a biocompatible scaffold that optimally enhances electron-transfer kinetics, retain mediators, and provide stability while ferrocene act as stable redox species used for signal amplification. The Fe-CM-β-CDMOF was characterized through Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), Thermogravimetric analysis (TGA), Dynamic light scattering (DLS) and field emission scanning electron microscopy (FE-SEM), Raman spectroscopy, atomic force microscopy (AFM) and each step of the sensor fabrication was observed using cyclic voltammetry (CV). The immunosensor was fabricated on graphite pencil electrode (GPE) using NHS/EDC chemistry to maintain biorecognition layer formation and retained bioactivity. Under the optimal conditions, the bioelectrode permitted to detect LF within the linear range of 1.0 х 10-2 -1000.0 ngmL-1, with a limit of detection 6.0 х 10-3 ngmL-1 and a response time of 45 min. The bioelectrode exhibited high selectivity, excellent reproducibility and stability over 12 days. The practical applicability of GPE/Fe-CM-β-CD-MOF/EDC-NHS/anti-LF antibody biosensor was demonstrated by detection of LF in milk and saliva samples, and good recovery values (98.0-102.0%) were obtained.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers