Ratiometric electrochemical-colorimetric dual-mode biosensor based on Cu-MOF and AuPt@PBA nanomaterials for ultrasensitive and accurate detection of DR1.
Yaping Zhang, Xiaohui Zhai, Heran Ma, Yanju Liu, Yang He, Huaixia Yang
College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou 450046, People's Republic of China. · College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou 450046, People's Republic of China. Electronic address: liuyanju886@163.com.
Key points
From the paper's conclusion- Here, a novel ratiometric electrochemical-colorimetric dual-mode biosensor was constructed using Cu-based metal-organic framework (Cu-MOF) and AuPt-modified prussian blue analog (AuPt@PBA), enabling ultrasensitive and accurate determination of DR1.
Abstract
Hashimoto's thyroiditis (HT) is a prevalent autoimmune disorder that increasingly threats human health and quality of life. As down-regulator of transcription 1 (DR1) is a key biomarker for HT, developing efficient DR1 detection methods is crucial for monitoring disease progression. Here, a novel ratiometric electrochemical-colorimetric dual-mode biosensor was constructed using Cu-based metal-organic framework (Cu-MOF) and AuPt-modified prussian blue analog (AuPt@PBA), enabling ultrasensitive and accurate determination of DR1. Cu-MOF was employed as an internal reference signal for electrochemistry, thereby enhancing the signal accuracy. AuPt@PBA can not only provide redox signals in electrochemical analysis, but also generate colorimetric signals in the presence of H2O2 due to its stable peroxidase-like activity, endowing the nanomaterial with excellent dual-mode sensing performance. Under optimized conditions, the biosensor exhibits a wide linear detection range of 1 × 10-1 pg/mL to 1 × 105 pg/mL in the ratiometric electrochemical mode and 1 × 10-1 pg/mL to 1 × 104 pg/mL in the colorimetric mode, with limits of detections (LODs) as low as 13.6 fg/mL and 28.9 fg/mL, respectively. The cross-validation between these two modes further improves the reliability. Moreover, the dual-mode biosensor demonstrates superior stability and strong anti-interference capability. Consequently, the biosensor holds potential for practical applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Traffic-light-type visual sensing of bilirubin: a dual-emission Au-Ag NCs/MOF-808/Tb nanocomposite based on an asynchronous quenching strategy.Mikrochimica acta · 2026
- Covalently functionalized graphene oxide with 2-aminoanthraquinone for construction of a ratiometric electrochemical biosensor toward cardiac troponin I quantification.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Solvent-Engineered Fe-Doped CuCo Prussian Blue Analogue Nanozyme with Enhanced Catalytic Activity for Dual-Mode Colorimetric and Electrochemical Immunoassays.Analytical chemistry · 2026
- New-Typed Co₃O₄@Co–Fe Oxide/AuNPs Double Nanoboxes Nanozyme Enables Bimodal Monitoring MetallothioneinsAnalytical Chemistry · 2025
- Bimetallic Valence Modulation Strategy Boosted Peroxidase-/Laccase-like Activity of a MoCu-2MI MOF Nanozyme for Portable-Device-Enabled Trimodal Sensing of D-Penicillamine and Colorimetric Analysis of Phenolic PollutantsAnalytical Chemistry · 2025
- Application of a magnetic biosensor based on novel cracker-shaped noble metal nanoparticles in dual-modal multidimensional detection of bladder cancer urinary biomarker HAase.Biosensors & bioelectronics · 2026