Improved measurement of GLP-1 concentrations in mouse plasma by ex vivo inhibition of neprilysin.

Chikayuki Funabashi, Tohru Hira

Hokkaido University, Graduate School of Agriculture, Kita-9, Nishi-9, Kita-ku, Sapporo, Hokkaido, 060-8589, Japan. · Hokkaido University, Research Faculty of Agriculture, Kita-9, Nishi-9, Kita-ku, Sapporo, Hokkaido, 060-8589, Japan. Electronic address: hira@eis.hokudai.ac.jp.

Preclinical

Key points

From the paper's conclusion
  • Our findings demonstrate that the addition of the NEP inhibitor to tubes is an effective strategy for the precise measurement of GLP-1 secretory dynamics, particularly in the measurement of multiple physiological parameters.

Abstract

Accurate measurement of plasma glucagon-like peptide-1 (GLP-1) in mice is hindered by its rapid degradation by dipeptidyl peptidase-4 (DPP-4) and neprilysin (NEP). In vivo administration of these inhibitors can stabilize plasma GLP-1. However, GLP-1-mediated physiological functions, such as enhancing insulin secretion and suppressing gastric emptying, can be artificially altered by these inhibitors. Here, we aimed to establish a simple and reliable ex vivo inhibition method by adding the NEP inhibitor, sacubitrilat, to collection tubes. The efficacy of sacubitrilat was validated through an in vitro GLP-1 degradation assay. The ex vivo method was then evaluated during meal and glucose tolerance tests for measurement of plasma GLP-1, and compared with an in vivo inhibition method, with plasma glucose, insulin, and gastric emptying measured in parallel. In the in vitro assay, sacubitrilat addition effectively prevented GLP-1 degradation. In meal and oral glucose tolerance tests, ex vivo sacubitrilat addition yielded markedly higher plasma GLP-1 concentrations compared to standard inhibitor cocktails containing DPP-4 inhibitor, enabling clear detection of nutrient-induced GLP-1 peak. This ex vivo approach did not influence plasma glucose, insulin, and gastric emptying, thus preserving the physiological integrity of the metabolic response. In contrast to the ex vivo inhibition method, the in vivo inhibition method yielded higher GLP-1 concentrations accompanied by lowered glucose, enhanced insulin, and reduced gastric emptying. Our findings demonstrate that the addition of the NEP inhibitor to tubes is an effective strategy for the precise measurement of GLP-1 secretory dynamics, particularly in the measurement of multiple physiological parameters.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers