Annals of vascular surgery

Long-term Outcomes After Medical and Surgical Management of Blunt Traumatic Aortic Injury.

Mohyee Ayouty, Joseph J DuBose, Marvin Lu, Lara Schwieger, Donna Bahroloomi, Donald Baril, Elizabeth L Chou, Cassra Arbabi,

Division of Vascular Surgery, Cedars-Sinai Medical Center, 8700 Beverley Boulevard, Los Angeles, CA 90048, USA. Electronic address: Mohyee.ayouty@cshs.org. · Department of Surgery, University of Texas at Austin, 1601 Trinity St., Building A, Austin, TX 78712, USA.

Key points

From the paper's conclusion
  • Both NOM and OM demonstrated favorable outcomes with low rates of treatment failure or re-intervention. TEVAR had low device-related complication rates. However, consistent follow-up remains a challenge in the trauma population.

Abstract

INTRODUCTION: Blunt traumatic aortic injury (BTAI) is a common cause of morbidity and mortality after blunt force. Management strategies include non-operative management (NOM) and operative management (OM). This study evaluated patterns of follow-up and outcomes using data from the international Aortic Trauma Foundation (ATF) registry. METHODS: The ATF prospective multicenter registry was queried for patients who had subsequent follow-up at participating centers after management of BTAI. Patients were stratified by injury grade. Collected data included demographics, imaging, medical therapy, complications, and need for re-intervention. RESULTS: 227 patients had follow-up data: Grade I (n=45), II (n=31), III (n=124), and IV (n=27). NOM was pursued in 86.7% of GI, 41.9% of GII, 7.2% of GIII, and 0% of GIV injuries while OM was performed in 13.3% of GI, 58.1% of GII, 90.4% of GIII, and 100% of GIV injuries. Anticoagulation was used in 15.7% and anti-platelet therapy in 46.4%. Five (2.2%) patients required re-intervention, mostly in GIII: 1 for failure of NOM, 2 for stent thrombosis, and 1 for subclavian steal. One patient with GII injury had reintervention for lesion progression. Morbidities (3.1%) included ischemia from left subclavian artery (LSA) coverage(n=5), embolic complication (n=1), and infection (n=1). Notably, there were no strokes, re-interventions for endoleak, or stent graft-related complications upon initial deployment. CONCLUSION: Both NOM and OM demonstrated favorable outcomes with low rates of treatment failure or re-intervention. TEVAR had low device-related complication rates. However, consistent follow-up remains a challenge in the trauma population.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers