From the paper's conclusion
  • UGTI was highly effective for iatrogenic femoral artery pseudoaneurysms, with high immediate and overall success and no observed complications. Procedural, anatomical, temporal, and hemostatic factors were associated with outcomes, while clinical failure and recurrence represented distinct treatment phases. These findings may support risk-adapted surveillance.

Abstract

BACKGROUND: Ultrasound-guided thrombin injection (UGTI) is effective for iatrogenic femoral artery pseudoaneurysms, but factors associated with early failure and recurrence remain incompletely defined. We evaluated treatment outcomes and their predictors. METHODS: This retrospective single-center study included 216 patients treated with UGTI between November 2023 and May 2026. Technical success was defined as immediate complete thrombosis after the first injection, clinical success as complete thrombosis at 24-hour Doppler follow-up, and recurrence as recanalization at 24 hours after technical success. Independent associations with clinical failure and recurrence were evaluated using multivariable logistic regression. RESULTS: Technical success was achieved in 204 patients (94.4%), clinical success in 176 (81.5%), and recurrence occurred in 31 of 204 patients (15.2%). Overall success without surgical or endovascular repair was 94.0%. Therapeutic index procedures (OR, 6.368; 95% CI, 2.037-19.910), INR >1.5 (OR, 5.286; 95% CI, 1.681-16.625), shorter neck length (OR per mm, 0.879; 95% CI, 0.802-0.964), a longer procedure-to-UGTI interval (OR per day, 1.041; 95% CI, 1.008-1.074), and platelet count <150,000/μL (OR, 3.407; 95% CI, 1.174-9.884) were independently associated with clinical failure. Therapeutic procedures (OR, 7.670; 95% CI, 2.094-28.090) and INR >1.5 (OR, 3.653; 95% CI, 1.114-11.982) independently predicted recurrence. No procedure-related complications occurred. CONCLUSIONS: UGTI was highly effective for iatrogenic femoral artery pseudoaneurysms, with high immediate and overall success and no observed complications. Procedural, anatomical, temporal, and hemostatic factors were associated with outcomes, while clinical failure and recurrence represented distinct treatment phases. These findings may support risk-adapted surveillance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers