Sex-Related Variation in Abdominal Aortic Dimensions and the Effect of Body-Size Indexing: A CT Study in Mexican Adults.
Clarissa Castillo, Oscar A De la Torre, V Jimena Lemus Colorado, Carolina Sulvaran Flores, Regina Díaz de León Derby, Erasmo de la Pena-Almaguer, Mario Alejandro Fabiani
The University of Texas Southwestern Medical School, Dallas, TX, United States. Electronic address: clarissa.castillo@utsouthwestern.edu. · Tecnológico de Monterrey, School of Medicine and Health Sciences, Monterrey, Nuevo Leon, México. Electronic address: oadltorre00@gmail.com.
Key points
From the paper's conclusion- In this non-pathological Mexican CT cohort, ASI was observed to attenuate baseline sex-related differences in abdominal aortic caliber, whereas height-based indexing AHI retained residual variation. These observations provide baseline reference parameters highlighting body scale and biological sex as relevant variables that warrant further investigation in larger, multi-center, and pathological cohorts to assess their clinical utility.
Abstract
BACKGROUND: This study evaluated the relationship between sex and abdominal aortic calibre and assessed whether Aortic Size Index (ASI) and Aortic Height Index (AHI) attenuate sex-related differences in a Mexican cohort without known vascular or aortic disease. METHODS: In this prospective study, 152 adults (58 males, 94 females) without known vascular pathology underwent CT imaging with measurements obtained perpendicular to the vessel centerline. Aortic diameters were measured at eight anatomical levels. ASI and AHI were calculated. Interobserver agreement was evaluated using intraclass correlation coefficients (ICC). RESULTS: Males had larger absolute infrarenal diameters than females (17.6 ± 2.0 vs. 14.9 ± 1.8 mm, p < 0.001). BSA indexing helped attenuate sex differences, yielding comparable ASI values between sexes (males 0.90 ± 0.14 vs. females 0.89 ± 0.12 cm/m2, p = 0.55; median sex difference 0.010 cm/m2), compared to an unadjusted median difference of 2.9 mm. Height indexing retained a significant sex difference (AHI: 1.01 ± 0.12 vs. 0.94 ± 0.12 cm/m, p < 0.001; median sex difference 0.090 cm/m). Interobserver agreement was excellent (ICC ≥ 0.90) at 6 of 8 anatomical levels. CONCLUSION: In this non-pathological Mexican CT cohort, ASI was observed to attenuate baseline sex-related differences in abdominal aortic caliber, whereas height-based indexing AHI retained residual variation. These observations provide baseline reference parameters highlighting body scale and biological sex as relevant variables that warrant further investigation in larger, multi-center, and pathological cohorts to assess their clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sex‐Based Differences in Long‐Term Outcomes of Patients With Ascending Aortic DilationJournal of the American Heart Association · 2025
- The Linear Association Between A Body Shape Index and Abdominal Aortic Calcification in Individuals With HypertensionClinical Cardiology · 2026
- Sex-Specific Differences in the Relationship of Atherogenic Index of Plasma and Abdominal Aortic CalcificationAngiology · 2026
- Z-Score Calculators for Cross Sectional Area to Height Ratio of the Aortic Root and Ascending Aorta in Healthy Children.Pediatric cardiology · 2026
- Comparing left atrial volume indexation methods for predicting major adverse cardiovascular events and atrial fibrillation: Data from the Akershus Cardiac Examination 1950 StudyEuropean Heart Journal · 2026
- Population-scale trends and variations in human aortic biomechanicsmedRxiv · 2026