The Annals of thoracic surgery

β-Blocker Use and Descending Thoracic Aortic Remodeling after Extensive Repair for Type A Aortic Dissection.

Haoyu Gu, Bowen Zhang, Yaojun Dun, Han Li, Xiaogang Sun

Department of Cardiovascular Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. · Department of Cardiovascular Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: xiaogangsunl@163.com.

Observational · n=1,147

Key points

From the paper's conclusion
  • In this observational study, postoperative β-blocker use was associated with slower aortic dilation at the diaphragmatic and celiac levels and higher rates of complete false lumen thrombosis in stent-covered and stent-uncovered DTA segments.

Abstract

BACKGROUND: Descending thoracic aorta (DTA) remodeling is a major determinant of late outcomes after extensive aortic arch repair for type A aortic dissection. This study evaluated the association between postoperative β-blocker use and long-term DTA remodeling after extensive repair. METHODS: From 2010 to 2019, 1,147 patients with type A aortic dissection who underwent extensive aortic arch repair were categorized into β-blocker (n=777) and non-β-blocker (n=370) groups. The main outcomes were overall survival, DTA dilation, and false lumen thrombosis. The additional outcome was DTA reintervention or rupture. RESULTS: The median follow-up was 64.0 months. β-Blocker use was not significantly associated with all-cause mortality (hazard ratio, 0.79; 95% confidence interval [CI], 0.50-1.26; P=0.32). β-Blocker use was associated with a slower increase in the DTA diameter at the diaphragmatic (β±standard error, -0.47±0.18; P=0.012) and celiac (β±standard error, -0.35±0.168; P=0.038) levels. At the pulmonary artery bifurcation level, a greater reduction in the aortic diameter was observed in the β-blocker group, although the difference was not significant (β±standard error, -0.242±0.123; P=0.051). β-Blocker use was associated with higher rates of complete false lumen thrombosis in stent-covered (hazard ratio, 1.21; 95% CI, 1.06-1.39; P=0.005) and stent-uncovered (hazard ratio, 1.49; 95% CI, 1.22-1.83; P<0.001) DTA segments. The cumulative incidence of DTA reintervention or rupture did not differ significantly between groups (subdistribution hazard ratio, 0.76; 95% CI, 0.47-1.22; P=0.25). CONCLUSIONS: In this observational study, postoperative β-blocker use was associated with slower aortic dilation at the diaphragmatic and celiac levels and higher rates of complete false lumen thrombosis in stent-covered and stent-uncovered DTA segments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

β-Blocker Use and Descending Thoracic Aortic Remodeling after Extensive Repair for Type A Aortic Dissection — Science Skim