Functional data for LDLR variant classification: comparative insights from high-content microscopy and flow cytometry assays.
Mohammad Majharul Islam, Ana Catarina Alves, Rafael Graça, Joana Rita Chora, Mafalda Bourbon, Simon G Pfisterer
Department of Anatomy, Faculty of Medicine, University of Helsinki, Finland. · Grupo De Investigação Cardiovascular, Unidade I&D, Departamento De Promoção Da Saúde E Doenças Não Transmissíveis, Instituto Nacional de Saúde Doutor Ricardo Jorge, Lisboa, 1749-016, Portugal; Centro Cardiovascular da Universidade de Lisboa, (CCUL@RISE, CAML), Faculdade de Medicina, Universidade de Lisboa, 1649-028, Portugal.
Key points
From the paper's conclusion- Microscopy assays show concordance with flow cytometry, consistent associations with lipid phenotypes and our OddsPath calculations support re-evaluation of evidence weights for microscopy assays.
Abstract
BACKGROUND AND AIMS: FH VCEP specifications for familial hypercholesterolemia variant interpretation assign a higher evidence weight to functional data from flow cytometry than microscopy assays. This restricts the use of microscopy assays for LDLR variant classification. We aimed to compare functional data obtained by both assays to determine whether microscopy-based assays could support a higher evidence level. METHODS: Fifty LDLR variants with available flow cytometry and microscopy data were compared for LDL uptake activity, including 21 newly characterized variants by microscopy. Variants were grouped by FH VCEP functional thresholds and results integrated with UK Biobank data to assess associations with lipid traits. RESULTS: We validated our microscopy assay with FH VCEP-classified control variants and compared functional activities measured by microscopy and flow cytometry assays, which showed significant correlation (r = 0.66, 95% CI: 0.473-0.795, p = 1.45 × 10-7) and a close average agreement (Bland-Altman bias = -0.05, 95% LoA: -0.69 to +0.60). Functional FH VCEP variant groups for both assays resulted in fair categorical agreement (Cohen's κ = 0.26, 95% CI: 0.018-0.479). Integration with UK Biobank data showed that carriers of variants with reduced LDLR activity (<70% and <50%) had higher LDL-C, total cholesterol, and ApoB levels compared to those with normal activity (>90%) for both microscopy and flow cytometry assays, with more pronounced differences observed at the <50% LDLR activity threshold. CONCLUSION: Microscopy assays show concordance with flow cytometry, consistent associations with lipid phenotypes and our OddsPath calculations support re-evaluation of evidence weights for microscopy assays.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- LDLR Variant Classification Through Activity-Normalized Prime Editing Screening.Circulation · 2026
- Plasma Lipidomic Phenotype Associated with Pathogenic LDLR Variants in Familial Hypercholesterolemia.International journal of molecular sciences · 2026
- The functional landscape of coding variation in the familial hypercholesterolemia gene LDLRScience · 2025
- In vitro analysis of the effects of intronic variants c.940+3_940+6del, c.941-3C>G, and c.2389+5G>A in the LDLR gene on pre-mRNA splicing using a minigene assay.Vavilovskii zhurnal genetiki i selektsii · 2026
- Putative protective role of PCSK9 variants in a multigenerational family with familial hypercholesterolemia.Atherosclerosis plus · 2026
- Promoter methylation of LDLR is not a common cause of familial hypercholesterolemia.medRxiv : the preprint server for health sciences · 2026