The Journal of arthroplasty

Comparative Diagnostic Accuracy of Multiplex PCR by Sample Type for Periprosthetic Joint Infection: A Systematic Review and Meta-Analysis.

Lina Wang, Hao Zhang, Li Cao, Zhongyuan Zhao, Chao Wan, Kun Song

Affiliated Hospital of Qingdao University, Department of Infectious Diseases, Qingdao, Shandong, China. · Yantai City Yantaishan Hospital, Department of Joint Surgery, Yantai, Shandong, China.

Meta-analysis

Key points

From the paper's conclusion
  • Sonicate fluid showed the highest diagnostic accuracy for pathogen identification after prosthesis removal, but its clinical utility is limited to the intraoperative setting. Synovial fluid remains the primary preoperative sample, though its limited sensitivity precludes its use as a standalone rule-out test. Given the limited evidence base for tissue samples, the choice of sample should be guided by clinical context. Future studies should focus on standardized protocols and further validation in larger cohorts.

Abstract

BACKGROUND: This systematic review and meta-analysis compared the diagnostic performance of multiplex polymerase chain reaction (mPCR) for periprosthetic joint infection (PJI) across three sample types: synovial fluid, periprosthetic tissue, and prosthetic sonicate fluid. METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we searched PubMed, EMBASE, and the Cochrane Library up to November 10, 2025. A total of 20 studies were included. We assessed study quality using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. For each sample type, we calculated pooled sensitivity and specificity and generated summary receiver operating characteristic (SROC) curves with their area under the curve (AUC). RESULTS: Diagnostic accuracy varied substantially by sample type. Sonicate fluid performed best, with pooled sensitivity of 0.72 (95% confidence interval [CI], 0.56 to 0.84), specificity of 0.98 (95% CI, 0.95 to 0.99), and an AUC of 0.95 (95% CI, 0.83 to 0.97). Synovial fluid showed moderate sensitivity of 0.62 (95% CI, 0.54 to 0.70), high specificity of 0.95 (95% CI, 0.91 to 0.97), and an AUC of 0.89 (95% CI, 0.76 to 0.94). Periprosthetic tissue had the lowest sensitivity of 0.23 (95% CI, 0.13 to 0.38), high specificity of 0.94 (95% CI, 0.85 to 0.98), and an AUC of 0.75 (95% CI, 0.16 to 0.83). CONCLUSIONS: Sonicate fluid showed the highest diagnostic accuracy for pathogen identification after prosthesis removal, but its clinical utility is limited to the intraoperative setting. Synovial fluid remains the primary preoperative sample, though its limited sensitivity precludes its use as a standalone rule-out test. Given the limited evidence base for tissue samples, the choice of sample should be guided by clinical context. Future studies should focus on standardized protocols and further validation in larger cohorts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.