There is a Marked Temporal Variation in the Level of Serological Markers Used for Diagnosis of Periprosthetic Joint Infection.
Mehmet Kürşat Yılmaz, Ahmad Abbaszadeh, Alexus M Cooper, Kamolsak Sukhonthamarn, Camilo Restrepo, Javad Parvizi
Kızıltepe State Hospital, Mardin, Türkiye. Electronic address: dryilmazkursat@gmail.com. · Joint Reconstruction Research Center, Tehran University of Medical Sciences, Tehran, Iran. Electronic address: ahmad.abbaszadeh2022@gmail.com.
Key points
From the paper's conclusion- Reliance on ESR and CRP for PJI diagnosis is substantial. There is temporal variation in serological markers for a given patient. Results of these laboratory tests can vary substantially, moving above or below the recognized thresholds, and can potentially interfere with the accuracy of these tests in the diagnosis of PJI.
Abstract
BACKGROUND: Previous studies have estimated systematic changes in erythrocyte sedimentation rate (ESR) and c-reactive protein (CRP) based on host and pathogen-related factors. This study sought to determine if a temporal variation of ESR and CRP is sufficient to affect infection diagnoses prior to arthroplasty revision. METHODS: This cohort consisted of 218 cases (129 ESR, 196 CRP) from 2001 to 2015 with at least two ESR and/or CRP measurements after primary arthroplasty and before their first revision surgery. Those who had measurements greater than 31 days before surgery, less than three months after previous surgery, or between two revision surgeries were excluded. The first ESR measurements were categorized as low (zero to 12.9 mm/hour), elevated (13 to 29.9 mm/hour), and high (≥ 30 mm/hour). The CRP was dichotomized as low (less than 1.0 mg/dL) or high (greater than 1.0 mg/dL). Thresholds were determined using diagnostic cutoffs from the 2018 Musculoskeletal Infection Society Definition of periprosthetic joint infection (PJI). RESULTS: The average ESR and CRP measurements were 2.16 and 2.20, respectively. The ESR increased 5.9% per day when initially low. Remaining relatively constant when elevated or high, CRP decreased 4.9% per day when the starting CRP was high and remained relatively constant when low. Bartlett's test showed differences in variance for ESR and CRP across all groups. Variation was most pronounced when initial ESR was low. CONCLUSION: Reliance on ESR and CRP for PJI diagnosis is substantial. There is temporal variation in serological markers for a given patient. Results of these laboratory tests can vary substantially, moving above or below the recognized thresholds, and can potentially interfere with the accuracy of these tests in the diagnosis of PJI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The diagnostic value of platelet-related indicators to CRP ratio in periprosthetic joint infection.Frontiers in cellular and infection microbiology · 2026
- The diagnostic role of albumin-based ratio markers for periprosthetic joint infection.Frontiers in cellular and infection microbiology · 2026
- Diagnostic Performance of Platelet‐to‐Mean Platelet Volume Ratio (PVR) in Periprosthetic Joint Infection: A Systematic Review and Meta‐AnalysisInternational Journal of Clinical Practice · 2026
- Association of Synovial Fluid White Blood Cell Count With Reinfection Risk Following Periprosthetic Joint Infection: A Nonlinear and Threshold Analysis.The Journal of arthroplasty · 2026
- Stratified Diagnostic Thresholds by Infection Chronicity Resolve the Controversy in Unicompartmental Knee Arthroplasty Periprosthetic Joint Infection: A Prospective Study.The Journal of arthroplasty · 2026
- Synovial Fluid Leukocyte Count and Differential Are Poor Standalone Rule-in Tests for Periprosthetic Joint Infection: Results of a Methodological Audit and Reanalysis of the 2025 Meta-analysis Underpinning the Unified Periprosthetic Joint Infection CriteriaClinical Orthopaedics and Related Research · 2026