The Journal of arthroplasty

Monoflange Versus Multiflange: Custom-Made Acetabular Implants in Revision Total Hip Arthroplasty.

Mari Babasiz, Alberto Alfieri Zellner, Tamara Babasiz, Elio Assaf, Frank Sebastian Fröschen, Andreas Christian Strauss, Dieter Christian Wirtz, Max Jaenisch

University of Bonn, Faculty of Medicine and University Hospital Bonn, Department of Orthopaedic and Trauma Surgery, Germany. Electronic address: Mari.Babasiz@ukbonn.de. · University of Bonn, Faculty of Medicine and University Hospital Bonn, Department of Orthopaedic and Trauma Surgery, Germany. Electronic address: Alberto.Zellner@ukbonn.de.

Observational

Key points

From the paper's conclusion
  • Monoflange CMACs demonstrated favorable clinical and radiographic outcomes and, after adjustment for patient factors, a significantly lower risk of implant removal than multiflange constructs. As implant design and era are confounded in this cohort, these findings should be interpreted as associations and require confirmation in prospective series.

Abstract

BACKGROUND: Severe acetabular bone loss remains a major challenge in hip reconstruction. Custom-made acetabular components (CMACs) represent a valuable treatment option, with monoflange designs potentially offering advantages over multiflange constructs by reducing implant size and soft-tissue exposure while maintaining mechanical stability. METHODS: This retrospective, single-center study analyzed 154 CMACs (101 monoflange and 53 multiflange) and assessed clinical outcomes (Oxford Hip Score), radiographic findings, complications, implant survival, and revision procedures. The mean follow-up was 37.0 months (range, 6.2 to 168.2), with longer follow-up for multiflange than monoflange constructs (55.5 versus 27.3 months; P = 0.011). RESULTS: Monoflange constructs showed shorter hospital stays (P = 0.030), reduced blood losses (P < 0.001), and shorter operative times (P = 0.006). Both groups improved in Oxford Hip Score (OHS), with higher postoperative scores for monoflange constructs (P = 0.010), although adjusted mean change in OHS did not differ (P = 0.566). Periprosthetic joint infection rates were higher for multiflange constructs (18.9 versus 6.9%; P = 0.034). Complete osseointegration was achieved in 93.1% of monoflange and 67.9% of multiflange constructs (P < 0.001). Horizontal center of rotation restoration was comparable (0.9 ± 5.0 versus 2.0 ± 5.7 mm; P = 0.236), whereas monoflange constructs showed less cranialization (3.5 ± 4.5 mm versus 7.6 ± 5.6 mm; P < 0.001). Multiflange design was associated with a higher risk of implant removal (odds ratio = 4.42; P = 0.007). CONCLUSION: Monoflange CMACs demonstrated favorable clinical and radiographic outcomes and, after adjustment for patient factors, a significantly lower risk of implant removal than multiflange constructs. As implant design and era are confounded in this cohort, these findings should be interpreted as associations and require confirmation in prospective series.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers