The Journal of arthroplasty

Accuracy of Published Projections of Hip and Knee Arthroplasty Utilization: A Systematic Review and Forecast-Validation Meta-Analysis.

Evelin Sára Antal, András Posta, Zoltán Bejek, Attila Szatmári, Gergely Holnapy, Bence Gusztáv Stubnya

Department of Orthopaedics, Semmelweis University, Budapest, Hungary. · Department of Orthopaedics, Semmelweis University, Budapest, Hungary. Electronic address: stubnya.bence@semmelweis.hu.

Meta-analysis

Key points

From the paper's conclusion
  • Published arthroplasty projections showed no consistent overall bias at the study-method level. Apparent accuracy depended on unit of analysis, pandemic-year inclusion, procedure definitions, and observed data sources.

Abstract

BACKGROUND: Published arthroplasty projections inform workforce, infrastructure, implant supply, and financing decisions, but their subsequent accuracy has not been comprehensively synthesized. METHODS: We conducted a systematic review and forecast-validation meta-analysis of studies reporting numerical projections of annual hip or knee arthroplasty utilization. The review was registered in the International Prospective Register of Systematic Reviews (PROSPERO). Projected values were matched with observed data from registries, health ministries, administrative datasets, the Organisation for Economic Co-operation and Development, the World Health Organization, or other official sources. To limit the influence of repeated projections from the same study, the primary analysis was performed at the study-method level; validation-pair-level and study-level analyses were secondary. RESULTS: There were 28 studies included in the qualitative synthesis. Quantitative validation included 93 directly comparable pairs from 17 studies and 23 study-method combinations. The primary study-method-level geometric mean predicted-to-observed (P/O) ratio was 1.00 (95% confidence interval [CI], 0.88 to 1.14; P = 0.983). The study-level P/O ratio was 1.01 (95% CI, 0.88 to 1.16; P = 0.868), while the secondary validation-pair-level P/O ratio was 1.13 (95% CI, 1.04 to 1.23; P = 0.005). In projections published before their target year, the study-method-level P/O ratio was 1.03 (95% CI, 0.81 to 1.32; P = 0.799). CONCLUSIONS: Published arthroplasty projections showed no consistent overall bias at the study-method level. Apparent accuracy depended on unit of analysis, pandemic-year inclusion, procedure definitions, and observed data sources.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers