Engineering Research Center for Seismic Disaster Prevention and Engineering Geological Disaster Detection of Jiangxi Province, East China University of Technology, Nanchang, 330013, China. · Engineering Research Center for Seismic Disaster Prevention and Engineering Geological Disaster Detection of Jiangxi Province, East China University of Technology, Nanchang, 330013, China. Electronic address: qbluo@ecut.edu.cn.
Key points
From the paper's conclusion- These results indicate that pXRF analysis of soil pellets prepared with microcrystalline cellulose can support geochemical anomaly screening and target prioritization in sandstone-type uranium exploration.
Abstract
This study evaluated portable X-ray fluorescence spectrometry (pXRF) using soil pellets supported by microcrystalline cellulose (MCC) for multielement geochemical screening in sandstone-type uranium exploration. Soil samples were collected at 104 sites at a depth of approximately 80 cm in the Hailijin and Qianjiadian districts, southwestern Songliao Basin. After air-drying, grinding, and sieving, pellets with MCC backing and rim support were prepared under a compaction load of 20 t held for 2 min and analyzed under laboratory conditions. Ti, Mn, Fe, Rb, Sr, Y, and Zr were consistently detected. U was excluded from quantitative analysis because its concentrations were near or below the effective detection threshold under the analytical configuration used. Following calibration with five soil certified reference materials, relative deviations from certified values for an independent validation material ranged from -7.8% to 6.9%. Between-pellet relative standard deviations were below 10% across three representative soil samples. Along the Hailijin H2 sampling line, jointly elevated Ti, Fe, and Sr concentrations occurred above both known mineralized sections and locally overlapped with elevated soil radon activity concentrations. R-mode cluster analysis and principal component analysis of the 33 Hailijin samples identified a Ti-Fe-Sr-Y-Zr association. The first principal component (PC1) explained 60.25% of the variance in the seven elements dataset. Applying the Hailijin derived PC1 index to Qianjiadian yielded scores above the reference screening threshold at three sites with complete seven elements measurements. A second area showed relatively high scores that remained below the screening threshold and requires further investigation. These results indicate that pXRF analysis of soil pellets prepared with microcrystalline cellulose can support geochemical anomaly screening and target prioritization in sandstone-type uranium exploration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of a Portable X-Ray Fluorescence Analyzer for Unconsolidated Sediments at Archaeological Sites: Capabilities and LimitationsQuaternary · 2026
- Feasibility of Laboratory X-ray Fluorescence for Estimating Extractable Soil Macronutrients in a Heterogeneous Soil ArchiveE3S Web of Conferences · 2026
- Comparing centred log ratio and conventional standardisation for principal component analysis of portable X ray fluorescence soil geochemistry in a peri urban retention basinDiscover Soil · 2026
- Advancing Quantitative XRF Analysis of Plant Matrices Through Validation and Extension of Element-Specific Correction Factors by Comparison with INAA Measurements.Methods and protocols · 2026
- Portable X-ray fluorescence (pXRF) analysis of heavy metals in contaminated soils: a case study from Varta Insel, HagenEnvironmental Geochemistry and Health · 2026
- Characterization of Fractionated Granite and Pegmatite Systems Using Portable X-Ray Fluorescence: Implications for LCT Pegmatite and Granite-Hosted Rare-Metal ExplorationMinerals · 2026