Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

A multi-thickness regression framework for determining photon attenuation parameters: Application to Sm2O3-doped tellurite glasses using MCNP6.2.

Diyar Çiftçi, Nuri Yorulmaz

Harran University, Graduate School of Natural and Applied Sciences, Department of Physics, Şanlıurfa, Türkiye. Electronic address: diyarciftci21@gmail.com. · Harran University, Faculty of Arts and Sciences, Department of Physics, Şanlıurfa, Türkiye. Electronic address: nyorulmaz@harran.edu.tr.

Key points

From the paper's conclusion
  • This study presents a statistically optimized multi-thickness regression framework for estimating photon attenuation parameters from Monte Carlo transmission data and demonstrates its applicability using Sm2O3-doped TeO2-Li2O-ZnO (TLZ:Sm) glasses.

Abstract

Reliable estimation of photon attenuation coefficients is essential for the characterization and optimization of radiation shielding materials. This study presents a statistically optimized multi-thickness regression framework for estimating photon attenuation parameters from Monte Carlo transmission data and demonstrates its applicability using Sm2O3-doped TeO2-Li2O-ZnO (TLZ:Sm) glasses. Linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), and fast neutron removal cross-section (FNRCS, ΣR) were evaluated over the photon energy range of 0.059-1.400 MeV corresponding to nine standard gamma-ray energies. Unlike conventional single-thickness calculations, the proposed framework combines Beer-Lambert's law with least-squares regression to estimate attenuation coefficients using transmission data from multiple sample thicknesses, thereby reducing statistical fluctuations and improving parameter consistency. The attenuation parameters were obtained from MCNP6.2 simulations and compared with theoretical XCOM and EpiXS data. The proposed regression framework showed excellent agreement with XCOM and EpiXS over the investigated energy range, with relative deviations below 1.0%. The results also demonstrate that the investigated TLZ:Sm glass system is a lead-free and transparent shielding material with competitive gamma- and neutron-shielding performance for potential applications in nuclear medicine and industrial radiation protection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers