From brittle ceramic to flexible shield: composition-tunable, lightweight gamma-ray shielding in lead-free MgFe2O4/HDPE nanocomposites.

S N Kane

School of Physics, D. A. University, Indore, 452001, India. Electronic address: kane_sn@yahoo.com.

Computational

Key points

From the paper's conclusion
  • This work computationally assesses the gamma-ray attenuation, buildup and mechanical behavior of lead-free magnesium nanoferrite (MgFe2O4, MgF)/high-density polyethylene (HDPE) composites as a function of MgF loading.

Abstract

Ionizing radiation shielding increasingly demands lightweight, non-toxic alternatives to conventional lead and concrete barriers. This work computationally assesses the gamma-ray attenuation, buildup and mechanical behavior of lead-free magnesium nanoferrite (MgFe2O4, MgF)/high-density polyethylene (HDPE) composites as a function of MgF loading. Five compositions (S1-S5), spanning 100-0 wt% MgF, were investigated. Mass and linear attenuation coefficients (MAC, LAC), half- and tenth-value layers, mean free path and buildup factors were computed over 0.015-15 MeV using Phy-X/PSD, and mechanical properties via the Voigt-Reuss-Hill approach with the rule of mixtures. All attenuation metrics varied monotonically with MgF content: pure MgF (S1) showed the highest LAC (0.3392 cm-1) and lowest half-value layer (2.04 cm) at 662 keV, although its MAC (0.0751 cm2/g) is lower than that of HDPE (0.0882 cm2/g) at this Compton-dominated energy, while HDPE-rich compositions retained mechanical flexibility, lower areal density, and superior fast-neutron moderation. Composite S2 (75MgF-25HDPE) emerged as the best practical compromise, combining strong attenuation with markedly lower brittleness than pure ceramic MgF. Benchmarked against lead, concrete and literature polymer systems, the present composites achieve a MAC within ∼11-24% of that of lead and above that of concrete at 662 keV, while being non-toxic and formable. MAC values from Phy-X/PSD, WinXCOM and EpiXS agree within RD ≤ 0.55% over 0.015-15 MeV, confirming inter-code consistency. These findings establish computational composition-performance design maps, which require experimental validation, for lightweight, wearable and space-constrained radiation-protection applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers