Influence of decay scheme incompleteness on coincidence summing corrections in γ-ray intensity measurements.
Tatsuya Miyazawa, Hiroaki Hayashi, Yasuaki Kojima, Michihiro Shibata
Graduate School of Engineering, Nagoya University, Nagoya, 464-8603, Japan. · College of Transdisciplinary Sciences for Innovation, Kanazawa University, Kanazawa, 920-1192, Japan.
Key points
From the paper's conclusion- These findings demonstrate that the q-based truncation provides a practical guideline for coincidence-summing corrections under conditions where decay schemes are partially incomplete.
Abstract
Accurate determination of γ-ray intensities is essential in nuclear physics and nuclear engineering, particularly for nuclei far from β stability. In close-geometry measurements using high-efficiency Ge detectors, true coincidence summing can significantly distort peak intensities and requires appropriate correction. In this study, the influence of decay scheme incompleteness on coincidence-summing corrections was quantitatively investigated using 152Eu and 154Eu. Incomplete decay schemes were systematically generated by removing γ-ray transitions according to the index q=εpIγ, defined as the product of the full-energy peak efficiency and the γ-ray intensity. Coincidence-summing corrections were evaluated using Monte Carlo simulations based on GEANT4. The results show that the corrected γ-ray intensities converge when transitions with q/qmax≥0.5% of the maximum are included, yielding agreement with reference data within approximately 5%. This behavior was consistently observed for both a 35% HPGe detector and a Clover detector. In addition, the magnitude of the correction increases with the weighted average total efficiency ⟨εt⟩, which serves as a qualitative indicator of summing effects, although it does not provide a strict quantitative accuracy criterion. These findings demonstrate that the q-based truncation provides a practical guideline for coincidence-summing corrections under conditions where decay schemes are partially incomplete.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of the ray-tracing Monte-Carlo code tRAYcy for geometry and coincidence-summing corrections in environmental gamma-ray spectrometry.Journal of environmental radioactivity · 2026
- Primary standardization and γ-ray emission intensity determination 166mHo at NRC.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Optimized Monte Carlo modeling of HPGe detector efficiency with true coincidence summing corrections using PHITS and MCNP5.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Coincidence counting of double-shell shot solid debris.The Review of scientific instruments · 2026
- Monte Carlo uncertainty propagation in efficiency calculations for 4πγ counting of 134 Cs and 137 CsMetrologia · 2026
- Influence of Radionuclide Cascade Decay Characteristics on Non-Collinear Coincidence Imaging Performance: A GATE-Based Monte Carlo Simulation Study.Biomedical physics & engineering express · 2026