Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Portable X-ray imaging of simulated radiological dispersal devices.

Erik Rajchl, Daniel Sas, Zbyněk Pokorný, Kamil Bednář

NBC Defence Institute, University of Defence, Vyškov, Czech Republic. Electronic address: erik.rajchl@unob.cz. · NBC Defence Institute, University of Defence, Vyškov, Czech Republic.

Key points

From the paper's conclusion
  • The findings indicate that radioactive material does not automatically prevent successful radiographic diagnostics of a suspected RDD, but the choice of imaging technology and detector has direct operational consequences for EOD response.

Abstract

Radiological dispersal devices (RDDs), often described as dirty bombs, represent a specific operational problem for explosive ordnance disposal (EOD) units because they combine the tactical requirements of an improvised explosive device response with radiation protection constraints. This article evaluates portable radiation detection and X-ray imaging systems under field conditions simulating radiological dispersal devices. Sealed sources of 137Cs and 60Co with activities ranging from 6.3 MBq to 4.74 GBq, together with a liquid 241Am source and an Am-Be neutron source, were placed in simulated IED configurations enclosed in metal, wood, cardboard and plastic. Dose-rate measurements were performed at 20 cm and 100 cm using an identiFINDER® R400 and a MultiRAE Pro multi-threat monitor. Radiographic diagnostics were performed using a NOVO digital X-ray system and a DÜRR computed radiography system. The results show that increasing source activity and gamma-ray energy substantially affect radiation detector performance and radiographic image quality. In contrast, the low-energy alpha emitter 241Am and the Am-Be neutron source had negligible effects on radiographic image quality despite presenting distinct detection challenges for field responders. The NOVO system maintained diagnostically useful images even in the presence of multi-giga-becquerel gamma sources, whereas the DÜRR system showed progressive radiation-induced image degradation, particularly for high-activity 60Co. The findings indicate that radioactive material does not automatically prevent successful radiographic diagnostics of a suspected RDD, but the choice of imaging technology and detector has direct operational consequences for EOD response. The findings provide practical guidance for equipment selection and integrated EOD-CBRN response to suspected RDD incidents.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers