Optical response of a water-washable 3D-printed photopolymer to gamma radiation.
B D G Mitidieri, D S Calheiro, L C Meira-Belo
Radiation Dosimetry Service, Center for Development of Nuclear Technology (CDTN), Belo Horizonte, Brazil. Electronic address: beatriz.cdtn@gmail.com. · Department of Anatomy and Imaging, Federal University of Minas Gerais, Belo Horizonte, Brazil; Center for Development of Nuclear Technology (CDTN), Belo Horizonte, Brazil. Electronic address: danielcalheiro@gmail.com.
Key points
From the paper's conclusion- Thus, water-washable photopolymers exhibit measurable, reproducible, and dose-dependent radiochromic responses at high doses, within the 100-500 kGy range, emerging as viable candidates for low-cost customizable detectors fabricated by additive manufacturing for radiation processing applications.
Abstract
Assessing the compatibility of the photon interaction parameters of radiochromic water-washable resins with reference dosimetric materials is crucial. Functional group, elemental composition, and microstructural modifications may affect the linear attenuation coefficient. Therefore, establishing correlations among these parameters is crucial to assess the operational reliability of additively manufactured resins under high-dose irradiation. In this study, we investigated the high-dose gamma irradiation response of a commercial water-washable photopolymerizable resin fabricated using masked stereolithography (mSLA) 3D printing. The samples were irradiated with 60Co gamma rays in the 100-500 kGy range, and their optical responses were evaluated by measuring their thickness-normalized absorbance using ultraviolet-visible light spectrophotometry. The dose-dependent growth of two absorption features at ∼420 and 500 nm caused the characteristic yellow coloration observed macroscopically. The effect of seven wavelengths within the 400-550 nm region was quantitatively analyzed using an asymptotic exponential model, and a comparative evaluation revealed 480 nm as the most stable and dose-discriminating wavelength within experimental uncertainties (95% confidence level, R2 = 0.995, maximum relative uncertainty of 13.2%). Chemical and morphological analyses (Fourier transform infrared spectroscopy and scanning electron microscopy combined with energy-dispersive X-ray spectroscopy) indicated changes consistent with radiation-induced modifications in the functional groups and microstructure. The experimentally measured linear attenuation coefficient of the resin was consistent with the values expected for polymeric materials in the megaelectron volt energy range. Thus, water-washable photopolymers exhibit measurable, reproducible, and dose-dependent radiochromic responses at high doses, within the 100-500 kGy range, emerging as viable candidates for low-cost customizable detectors fabricated by additive manufacturing for radiation processing applications. However, future investigations into long-term signal stability and formulation variability remain necessary before their possible routine practical adoption.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiation-Sensitive Thin Film Dosimeter Based on Polyvinyl Alcohol (PVA)/Hafnium Dioxide (HfO2)/Silver Nitrate (AgNO3) Composite: Colorimetric Characterization and Dose-Response Analysis for Low-Dose Gamma-Ray Applications.Polymers · 2026
- The influence of post‐curing protocols on the optical properties of provisional and long‐term 3D‐printable resin compositesEuropean Journal Of Oral Sciences · 2026
- Chromatic Stability of Three Photopolymerizable Resins for Additive Manufacturing Following Immersion in Artificial Saliva: A Comparative Spectrophotometric Analysis.Journal of functional biomaterials · 2026
- Evaluation of a salicylic-acid-based Fricke gel for gamma radiation dosimetry.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Effect of fractionated therapeutic radiotherapy on surface microhardness and roughness of giomer- and ormocer-based restorative composites: an in vitro studyScientific Reports · 2026
- Compatibility of PVC after irradiation: spectroscopic evaluation.European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences · 2026