Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

The application of neural network models in the measurement of passive neutron multiplicity for large-mass special nuclear materials.

Yusen Huang, Jinlong Yong, Yushou Song, Huilan Liu

College of Nuclear Science and Technology, Harbin Engineering University, Harbin, 150001, China. · College of Nuclear Science and Technology, Harbin Engineering University, Harbin, 150001, China. Electronic address: songyushou80@163.com.

Computational

Key points

From the paper's conclusion
  • Therefore, in this work, the bias induced by the point model assumption was quantified using the one-speed neutron transport equation and Monte Carlo simulations.

Abstract

Accurate and reliable mass measurement of special nuclear materials (SNMs) is of vital importance for nuclear safeguards. Although the point model assumption simplifies the derivation of the neutron multiplicity counting (NMC) equation, it limits the quantitative analysis capability for SNMs with large masses. Given the high cost and widespread deployment of thermal neutron multiplicity counters, improving their performance in safeguard supervision is of practical significance. Therefore, in this work, the bias induced by the point model assumption was quantified using the one-speed neutron transport equation and Monte Carlo simulations. Furthermore, artificial neural network (ANN) models were employed to replace some of the mathematical relations in the NMC equation, to enhance the measurement capability of the NMC method for larger-mass SNMs. By comparing the calculation results of the transport equation and the Geant4 toolkit for the leakage multiplication factor and factorial moments, it is found that the point model systematically underestimates the process of neutron multiplication within the material. The degree of underestimation is directly proportional to the mass and volume of SNM, and has a certain correlation with the geometric shape of the material. By integrating the ANN algorithm into the NMC equation, the verification results show that the ANN model can significantly reduce the measurement bias of SNM mass for the NMC equation. Specifically, for the plutonium scrap multiplicity counter, the application of the ANN model can reduce the measurement deviation of 240Pu mass from 19.22% to 1.79%, and can also predict the mass of 239Pu in SNM.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

The application of neural network models in the measurement of passive neutron multiplicity for large-mass special nuclear materials — Science Skim