Dosimetry validation via EGS5 Monte Carlo simulation, microbial inactivation kinetics, and quality preservation of frozen sliced squid (Loligo spp.) under 10 MeV electron beam irradiation.
Sy Minh Tuan Hoang
Thu Dau Mot University, 06 Tran Van On, Phu Loi Ward, Ho Chi Minh City, 700000, Viet Nam. Electronic address: hoangsyminhtuan@tdmu.edu.vn.
Key points
From the paper's conclusion- These results support 2 kGy dual-beam e-beam processing as a technologically sound, quantitatively validated intervention for frozen cephalopod safety and quality assurance.
Abstract
High-energy (10 MeV) electron beam (e-beam) irradiation was investigated as a non-thermal intervention for vacuum-packaged frozen sliced squid (Loligo spp.). Absorbed doses ranged from 1 to 5 kGy, with storage at -18 °C for eight weeks. A core challenge was dosimetry mapping within deep-frozen bulk geometries, since standard B3 thin-film dosimeters lose chemical validity below their glass transition temperature. This was addressed using the Electron Gamma Shower version 5 (EGS5) Monte Carlo code. A dual-beam configuration achieved a Dose Uniformity Ratio (DUR) of 1.18, confirmed via B3 dosimetry in a density-matched phantom, with agreement within 1.7%. Sensitivity analysis showed a 10% fluctuation in phantom density did not raise the DUR beyond 1.28, confirming robustness against packaging variation. Using a high-bioburden challenge model with an initial Total Viable Count (TVC) of 6.8 log CFU/g, the 2 kGy treatment reduced TVC to 2.6 log CFU/g, a 4.2-log reduction, remaining below the 6.0 log CFU/g threshold throughout storage. Lipid oxidation, tracked via Peroxide Value (PV) and Thiobarbituric Acid Reactive Substances (TBARS), followed zero-order kinetics; the 2 kGy treatment yielded a final TBARS concentration of 0.68 mg MDA/kg, below the 1.0 mg MDA/kg sensory rejection threshold. Total color difference (ΔE*) and Warner-Bratzler shear force changes remained within commercially acceptable limits. A discriminative Triangle Test (ISO 4120:2021) detected no statistically significant organoleptic difference, though post-hoc power analysis indicated limited power for strict equivalence. These results support 2 kGy dual-beam e-beam processing as a technologically sound, quantitatively validated intervention for frozen cephalopod safety and quality assurance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physicochemical and microbial changes in Raw beef meat induced by radiationFood Science of Animal Resources · 2026
- Effects of Electron Beam Irradiation on the Storage Stability and Quality Characteristics of Chicken and Duck MeatFoods · 2025
- Electron beam processing of freeze-dried and frozen raw pet food to eliminate Salmonella and Listeria monocytogenes: efficacy and nutritional impact.Frontiers in veterinary science · 2026
- Dose-dependent refractive index changes in megavoltage X-ray-irradiated high-density polyethylene measured by terahertz time-domain spectroscopy.Biomedical physics & engineering express · 2026
- Evaluation of a fast kV switching dual energy CT in deriving relative stopping power using tissue equivalent phantoms of various sizesMedical Physics · 2026
- Impact of electron-beam dose on microbial diversity and succession dynamics of refrigerated poultry meat during extended storage.Poultry science · 2026