Dose dependent immune and antioxidant in responses to low dose radiation.
Ahmed E Yousif, Mahmoud H Abdelgawad, Khaled Abdelaziz Kamal, I H Ibrahim, M S Talaat, Omar S Desouky
Clinical Oncology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt; Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt. Electronic address: AhmedEYousif@med.asu.edu.eg. · Physics Department, Faculty of Science, Al-Azhar University, Cairo, Egypt.
Key points
From the paper's conclusion- The results showed a gradual increase in immune markers with rising dose: CD4+ values were 31.62 ± 5.89, 39.17 ± 0.96, 49.33 ± 4.49 and 62.23 ± 0.83%, while CD8+ values were 29.23 ± 2.26, 32.83 ± 3.5, 46.40 ± 1.57 and 55.47 ± 2.14% for the control, 0.1 Gy, 0.25 Gy and 0.5 Gy groups respectively.
Abstract
Radiotherapy is a cornerstone of cancer treatment, aiming to deliver the prescribed dose to tumor tissue while minimizing the risk of toxicity to surrounding healthy organs. Recently, low-dose radiation has gained attention for its potential biological and immunomodulatory effects. Low-dose radiation is also suggested to exert favorable biological effects; a concept often associated with radiation hormesis. This study aims to investigate the dependent impact of different low radiation doses on immune parameters and antioxidant activity. To examine this hypothesis, healthy rats were exposed to whole-body irradiation at 0.1 Gy, 0.25 Gy, and 0.5 Gy. Blood samples were collected 24 h post-irradiation to measure CD4+ and CD8+ T-cell levels using flow cytometry, while antioxidant enzymes (SOD, CAT, and GPx) were quantified spectrophotometrically. The results showed a gradual increase in immune markers with rising dose: CD4+ values were 31.62 ± 5.89, 39.17 ± 0.96, 49.33 ± 4.49 and 62.23 ± 0.83%, while CD8+ values were 29.23 ± 2.26, 32.83 ± 3.5, 46.40 ± 1.57 and 55.47 ± 2.14% for the control, 0.1 Gy, 0.25 Gy and 0.5 Gy groups respectively. Antioxidant enzymes showed an increase at 0.1 Gy (SOD: 13.46 ± 1.15, CAT: 66.98 ± 0.97, GPx: 33.28 ± 1.48 U/mL), followed by decreases at 0.25 Gy (SOD: 5.86 ± 0.56, CAT: 43.35 ± 1.93, GPx: 21.10 ± 1.30 U/mL) and 0.5 Gy (SOD: 4.18 ± 0.56, CAT: 29.45 ± 1.09, GPx: 13.57 ± 0.65 U/mL). Effect-size analysis further clarified the magnitude of biological changes across doses. Based on these findings, the observed pattern suggests a hormetic-type response under the experimental conditions, where 0.1 Gy enhances immune and antioxidant activity, while higher doses (0.25-0.5 Gy) continue to stimulate immune parameters but induce oxidative stress. These findings provide insight into dose-dependent immune and redox responses to low-dose radiation and may provide a basis for future preclinical investigations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Low-dose radiotherapy as an immunomodulator in cancer: dose-specific mechanisms and hybrid high-dose/low-dose strategies.Biomarker research · 2026
- Prediction of the Dose and Dose-Rate of Ionizing Radiation that Provides the Greatest Biological Benefit.Dose-response : a publication of International Hormesis Society · 2026
- When Is 4Gy Enough? Defining Dose Sufficiency and Durable Control in Indolent B-Cell Lymphoma.Critical reviews in oncology/hematology · 2026
- Microdosimetry and biological effectiveness of 35 radionuclides for targeted tumor therapy: alpha, beta, and low-energy electron emitters.International journal of radiation biology · 2026
- The ALARA dilemma: reconciling scientific uncertainty, biological evidence, and the future of dose-response governance in radiation protection.Archives of toxicology · 2026
- Review of radiobiological dose rate effects at the edge between conventional and FLASH.Physics in medicine and biology · 2026