Medical Physics and Radiation Sciences Program, School of Physics, Universiti Sains Malaysia, Penang, 11800, Malaysia. Electronic address: ramzun@usm.my. · Medical Physics and Radiation Sciences Program, School of Physics, Universiti Sains Malaysia, Penang, 11800, Malaysia; Isa Kaita College of Education, Dutsin-Ma, Katsina State, Nigeria. Electronic address: nuragambodtm905@gmail.com.
Key points
From the paper's conclusion- This study presents an integrated experimental and deterministic modelling framework for evaluating 17 naturally occurring radioactive building materials collected in Katsina State, Nigeria.
Abstract
Conventional radiological assessment of building materials predominantly relies on empirical hazard indices that provide screening information but do not explicitly describe photon transport within finite material geometries. This study presents an integrated experimental and deterministic modelling framework for evaluating 17 naturally occurring radioactive building materials collected in Katsina State, Nigeria. Activity concentrations of 226Ra, 232Th and 40K were measured using NaI(Tl) gamma-ray spectrometry and used as source-term inputs to a deterministic photon-transport model based on the diffusion approximation of the Linear Boltzmann Transport Equation (LBTE). The governing equation was solved numerically using the Finite Element Method (FEM) for a representative slab geometry. Conventional radiological indices were also calculated for screening purposes. The measured activity concentrations were 18.80-45.50 Bq kg-1 for 226Ra, 14.82-93.70 Bq kg-1 for 232Th and 130.80-489.70 Bq kg-1 for 40K. The deterministic calculations produced spatial photon-flux and surface-dose estimates for the representative geometry. Comparison with conventional dose estimates gave r = 0.990 and R2 = 0.980, with RMSE = 51.95 nGy h-1 and MAE = 49.85 nGy h-1. Because both calculations use the same measured radionuclide concentrations, these statistics are interpreted as a numerical consistency assessment rather than independent validation. The study therefore demonstrates a proof-of-concept deterministic framework; independent experimental dose measurements and/or Monte Carlo benchmarking are required before quantitative predictive validity can be claimed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RESRAD‑Build Simulation of Indoor Radiation Exposure Pathways in Nigerian Residential BuildingsInternational Journal of Computer Applications · 2026
- Assessment of natural radioactivity and radiological indices in concrete used for apartment construction in Korea.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Risk assessment and management model for gamma radiation in building materialsRadiation Physics and Chemistry · 2026
- Investigation of naturally-occurring radioactive materials (NORM) in building materials in Ireland.The European physical journal. Special topics · 2026
- Indoor radon exposure in Obuasi mining community: influence of dwelling materials and annual effective dose assessment.Radiation protection dosimetry · 2026
- Thermophysical characterization of building materials due to radioactive decayConstruction and Building Materials · 2026