Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Ultra-high-fidelity reactor pressure vessel monitoring using SERF magnetometer arrays.

Ronald R M Mahomane, Marius Tchonang Pokaha, Manny Mathuthu

University of the Witwatersrand, Faculty of Health Sciences, 1 Jan Smuts Avenue, Braamfontein, Johannesburg, 2000, South Africa. · Necsa - The South African Nuclear Energy Corporation SOC Ltd, Elias Motsoaledi Street Extension (Church Street West), R104 Pelindaba, Madibeng, Brits, North West, 0240, South Africa.

Computational

Key points

From the paper's conclusion
  • Simulations indicate that an eight-sensor gradiometric SERF array placed on the biological shield wall at approximately 2.5m provides adequate shielding for alkali-vapor cell operation while maintaining sensitivity to permeability perturbations within the RPV wall.

Abstract

Continuous surveillance of Reactor Pressure Vessels (RPVs) in Pressurized Water Reactors (PWRs) is critical for Long-Term Operation (LTO), yet conventional inspection techniques typically require reactor shutdowns or direct access to high-radiation environments. This study proposes a physics-based Digital Twin framework for remote, non-intrusive monitoring of RPVs using Spin-Exchange Relaxation-Free (SERF) magnetometers. The Digital Twin is formulated as a physics-informed computational surrogate coupling first-principles neutron transport with magnetostatic field modeling and validated constitutive material laws to infer irradiation-induced embrittlement without breaching the pressure boundary. Because full-scale experimentation in operating PWRs is constrained by radiological conditions, the framework is validated using benchmark methodologies employed in safety-critical nuclear analysis, including comparison with International Atomic Energy Agency (IAEA) Coordinated Research Project reference data and reported post-irradiation magnetic measurements. Simulations indicate that an eight-sensor gradiometric SERF array placed on the biological shield wall at approximately 2.5m provides adequate shielding for alkali-vapor cell operation while maintaining sensitivity to permeability perturbations within the RPV wall. The configuration achieves a detection margin of 3.3×108 relative to background magnetic noise, with constitutive validation yielding a Mean Absolute Error of 2.7%.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Ultra-high-fidelity reactor pressure vessel monitoring using SERF magnetometer arrays — Science Skim