Robotic Assessment of Thumb Proprioception after Stroke: Reliability, Validity, and Sensitivity.
Luis Garcia-Fernandez, Andria J Farrens, Vicky Chan, Raymond D Rojas, Eric T Wolbrecht, Joel C Perry, An H Do, Steven C Cramer,
Mechanical and Aerospace Engineering Dept., University of California Irvine, Irvine, California. Electronic address: garciaf7@uci.edu. · Mechanical and Aerospace Engineering Dept., University of California Irvine, Irvine, California.
Key points
From the paper's conclusion- SCJ is a reliable, valid, and sensitive assessment of dynamic thumb proprioception after stroke. It revealed that thumb proprioceptive deficits are common and related to finger proprioception deficits, supporting its use in future studies of sensory impairment and rehabilitation outcomes.
Abstract
OBJECTIVE: Despite the thumb's critical role in dexterity and its dense sensory innervation, thumb proprioceptive deficits after stroke remain limited due to the limited nature of clinical assessments. This study evaluated the reliability, validity, and sensitivity of a novel robotic assessment of thumb proprioception, SomatoCircleJump (SCJ), in individuals with chronic stroke. DESIGN: Cross-sectional psychometric study evaluating the reliability, validity and sensitivity of SCJ using baseline data from a clinical trial, with assessments conducted twice 5-10 days apart. In SCJ, a robot moved the visually occluded thumb, and participants indicated when the thumb passed a visual target. SETTING: University-based rehabilitation research laboratory. PARTICIPANTS: Thirty-five stroke survivors with residual unilateral hand weakness and 24 healthy age-matched controls. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: SCJ proprioceptive error, defined as the angular difference between actual thumb position and the visually presented target. Test-retest reliability was assessed with Intraclass Correlation Coefficient (ICC). Validity and sensitivity were evaluated by comparing SCJ with the Fugl-Meyer Assessment Sensory Scale for the upper extremity (FMA-S) thumb position item, and two robotic proprioception tests, one for the thumb (ThumbSense) and one for the fingers (Crisscross). RESULTS: SCJ demonstrated good test-retest reliability (ICC = 0.82, 95% CI [0.72-0.87]). SCJ error correlated significantly with FMA-S (ρ = -0.56, p < 0.001), ThumbSense accuracy (ρ = -0.62, p < 0.001), and Crisscross error (ρ = 0.61, p < 0.001). Using a 2SD criterion relative to controls, SCJ identified thumb proprioceptive impairment in 61% of stroke participants, compared with 23% identified by FMA-S. CONCLUSIONS: SCJ is a reliable, valid, and sensitive assessment of dynamic thumb proprioception after stroke. It revealed that thumb proprioceptive deficits are common and related to finger proprioception deficits, supporting its use in future studies of sensory impairment and rehabilitation outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validity and Reliability of the 6-Minute Pegboard and Ring Test in Individuals with Spinal Cord InjuryMeasurement in Physical Education and Exercise Science · 2026
- Test-Retest Reliability of Hierarchical Proprioception Assessment of the WristmedRxiv · 2026
- Beyond Psychophysics: A Physiological Marker of Proprioceptive Function After Stroke.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- A portable biomedical device for post-stroke spasticity assessment: preliminary validation studyResearch on Biomedical Engineering · 2026
- Reliability and validity of the Upper Limb Performance Assessment for functional prehension tasks in adults with stroke: A prospective study.Clinical rehabilitation · 2026
- Bilateral Mechanoreception Discrimination based on Bihemispheric Somatosensory Response Patterns is Associated with Proprioception and Motor Function After Stroke.bioRxiv : the preprint server for biology · 2026