Intercell nonuniformity and dominant mechanisms analysis in industrial-scale water electrolyzer stacks: a unified comparative multiphysics modeling across AWE, AEM and PEM
Ang Lu, Danji Huang, Qunlei Wen, Shichang Cui, Wenxin Liu, Hao Li, Tianyu Hu, Xiaomeng Ai,
State Key Laboratory of Advanced Electromagnetic Engineering and Technology · Hitachi (Japan)
Key points
From the paper's conclusion- To address this issue, this study develops a unified stack-scale multiphysics lumped-parameter model for industrial-scale alkaline water electrolysis (AWE), anion exchange membrane water electrolysis (AEM), and proton exchange membrane water electrolysis (PEM) stacks and uses it to compare the dominant mechanisms of intercell nonuniformity across the three technologies.
Abstract
Low temperature water electrolysis is a key route for converting renewable electricity into green hydrogen, but industrial-scale stacks are prone to intercell nonuniformity during scale up. The origins and dominant mechanisms of this nonuniformity remain unclear across different electrolyzer technologies. To address this issue, this study develops a unified stack-scale multiphysics lumped-parameter model for industrial-scale alkaline water electrolysis (AWE), anion exchange membrane water electrolysis (AEM), and proton exchange membrane water electrolysis (PEM) stacks and uses it to compare the dominant mechanisms of intercell nonuniformity across the three technologies. The model is formulated on a common stack-level basis and couples flow distribution, shunt current, bubble coverage, temperature distribution, and electrochemical reaction under a common external flow network. The common stack-level framework is first validated using an AWE experimental platform. The model results show that AWE exhibits the strongest intercell nonuniformity, mainly due to shunt current induced redistribution of effective reaction current. AEM shows intermediate behavior governed by weak shunt current and gas-phase effects, whereas PEM is influenced mainly by bubble coverage and temperature development. Load dependent and layered physical field analyses further reveal that AWE is dominated by shunt current, causing a 12.38% rated current loss and a 7.21% energy-efficiency drop, whereas the responses of AEM and PEM are governed mainly by voltage efficiency degradation, driven by gas-phase and temperature effects. The proposed framework provides a unified basis for mechanism identification and differentiated optimization of industrial-scale low temperature electrolyzer stacks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multiphysics Modeling of Coupled Multiphase Transport and Electrocatalysis in Industrial Zero-Gap Alkaline Water Electrolyzers: Cell Size and Flow Field EffectsCatalysts · 2026
- Review and expectation of modeling methods research on alkaline electrolyzer for hydrogen productionRenewable and Sustainable Energy Reviews · 2026
- Anion exchange membrane electrolysis beyond the lab scale: a review on research and industry stacksCurrent Opinion in Chemical Engineering · 2026
- Renewable Intermittency Redistributes Catalyst Recovery and Membrane Degradation in Anion Exchange Membrane Water ElectrolysisAdvanced Energy Materials · 2026
- Influence of dynamic operating cycles on the performance and degradation of PEM electrolyzers: a combined electrical, electrochemical, and morphological analysisEnergy Conversion and Management · 2025
- Mass Transfer Intensification via Intra-Diaphragm Gap Feeding in Alkaline Water ElectrolysisIndustrial & Engineering Chemistry Research · 2026