Frequency and Causes of Waveform Capnography Failure After Successful Emergency Tracheal Intubation.
Brian E Driver, Aaron E Robinson, Joanna Kuo, Matthew E Prekker
Department of Emergency Medicine, Minneapolis, MN. Electronic address: brian.driver@hcmed.org. · Department of Emergency Medicine, Minneapolis, MN.
Key points
From the paper's conclusion- CO2 waveform failure occurred in approximately 4% of successful intubation procedures.
Abstract
STUDY OBJECTIVE: Multidisciplinary guidelines recommend waveform capnography as the preferred method for determining endotracheal tube location after intubation and advise immediate tube removal when the waveform is absent or inadequate unless a fault can be immediately identified and corrected. Because capnography depends on several components that can each fail, an absent waveform does not always indicate an esophageal tube, and removing a correctly placed tube exposes a critically ill patient to the risks of reintubation. How often waveform capnography fails despite correct tracheal placement has been estimated only from trials of colorimetric detectors in populations with high proportions of cardiac arrest, and the causes have not been described. METHODS: We performed a retrospective analysis of a prospectively collected continuous quality improvement database of emergency intubations at an urban, safety-net hospital, including patients aged ≥14 years intubated between January 1, 2022, and April 21, 2025. Trained observers collected intubation data in real time, and the intubating physician completed a structured form after each procedure. The primary outcome was CO2 waveform failure following successful tracheal intubation. Secondary outcomes were the reported cause of failure and whether the tube was removed. RESULTS: Of 2,875 successful tracheal intubation procedures, 124 (4.3%; 95% confidence interval 3.6 to 5.1%) had CO2 waveform failure despite the tube being located in the trachea. Human error accounted for 83 events (67%), nearly all of which were from the CO2 sampling line not being connected to the bag or the monitor (82 events, 66%). Identified equipment failure accounted for 11 events (9%). The cause was undetermined in 33 events (27%), including 30 (24%) in which the failure was never explained despite confirmed tracheal placement and 3 in which the cause was not formally categorized. The endotracheal tube was removed because of the absent waveform in 1 event (1%). CONCLUSION: CO2 waveform failure occurred in approximately 4% of successful intubation procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Protocol and Statistical Analysis Plan for the Waveform Capnography versus Colorimetric Carbon Dioxide Detection During Tracheal Intubation of Critically Ill Adults (WAVE) StudymedRxiv · 2026
- Management of a "Can Intubate, Can't Ventilate" Airway Post-tracheostomy: A Case Report.Cureus · 2026
- Airway ultrasound versus capnography to confirm endotracheal intubation: protocol for a systematic review and meta-analysis.Systematic reviews · 2026
- Validity of transcutaneous capnometry in prolonged use in a patient population with acute respiratory failureRespiratory Medicine · 2026
- Misleading Capnography in Acute Pulmonary Embolism: Case Series of Masked End-Tidal CO2 Response During Airway Management.Journal of investigative medicine high impact case reports · 2026
- The use of Capnometry in Prehospital Intubation and Association with 30-Day Mortality: A Nationwide Registry Study.Prehospital emergency care · 2026